  1. A

    new conventional boiler

    Im going to be fitting new for old. the only thing is the existing system has gravity primary's. I am going to fit 2 zone valve's but i am looking for advice on where to fit the pump as i know it can cause problems.
  2. A

    Worcester cdi DT20 controlls

    On the twin channel programmer for this boiler. Does the hot water setting just preheat the water in the boiler when it is on
  3. A

    Vokera linea 24

    This boiler keeps losing pressure. on inspection i noticed the blow off is dripping constantly. At first i tried to check the expansion vessel, the valve would not let air in or out though. Need some help with what needs done guys :roll:
  4. A

    Gravity primarys

    can new heat only boilers still be fitted to a system with gravity primarys. Does it need to be a floor standing boiler?
  5. A

    Standard efficency combi

    Is it still o.k to fit a SE combi where there is no possible place to take a condensate pipe
  6. A

    flushing a system

    Can someone tell me a good procedure for cleaning and flushing a central heating system before changing a boiler
  7. A

    Systen boiler or heating only boiler

    I was looking for a boiler to replace and old one. The system will still have a hw cylinder. In a brochure i have there are system boilers and heating only boilers, whats the difference
  8. A

    HW cylinder with no drain

    I recently had this problem, the drain valve on the cylinder was broken. I disconnected the top connection and siphoned out as much as i could then lifted out the cylinder. Is this the easiest way or are there other methods
  9. A

    system with no drain

    What is the best way to drain a heating system with no draining point.
  10. A

    hep pipe

    Are hep inserts for compression fittings only or should they always be used
  11. A

    Combi regulations

    Is it now a reg to fit a room stat with combi boilers
  12. A

    Best combi on the market

    I work for a company who fit and recommend Worcester. I usually fit the Greenstar CDi models. Just wondering what everyone else fits or rates the best. I personally find worcester make it very easy for the installer and manufacture very intelligent boilers
  13. A

    Back boilers

    The 1st time i changed a back boiler for a combi i took the back boiler an gas fire out. Is it ok to disconnect the flow and return to the back boiler and leave it in so i dont disturb the gas fire