    Help Needed - Bathroom Downlight Problem

    The bathroom downlight above the shower cubicle stopped working yesterday. The fitting is an Aurora IP65 fireproof downlight. I removed the fitting and put in a new bulb. It still wouldn't work. Tried another bulb just in case and still nothing. I checked with a multimeter that there was...
  2. N

    Electric Underfloor Heating Thermostat Replacement

    Our underfloor heating thermostat is faulty. To replace it with the same model as currently fitted it would cost £60. I have been looking for a replacement online and see that they all seem to come with 10k temperature probes whereas our original one has a 110k temperature probe. Would a...
  3. N

    Vaillant Ecomax 635 F.25 and no water pressure

    Every two weeks or so when waking up in the morning there is no hot water and no heating. Boiler shows F.25 and the water pressure is 0. So the pressure must be getting too high which causes the PRV to open. This also seems to start to happen every year when the colder weather comes. Last...
  4. N

    BOSCH Condenser Dryer Tripping RCD

    Bosch condenser dryer model WTE69, 3 years old. The filter indicator light on the dryer was illuminating during the cycle. The door filter is cleaned regularly and was clean but we gave it a thorough clean dryed it out. Next time we used the dryer the same happened. So we re-cleaned the...
  5. N

    Device to alert you to a power failure

    Just after midnight this morning while watching tv the main RCD tripped on the consumer unit. None of the MCBs had gone off. I reset the RCD and checked the fridge etc was back on. Everything was fine afterwards so I went to bed. This morning woke up and house was cold, water cold. Went in...
  6. N

    Vaillant engineer left nuts inisde boiler?

    //www.diynot.com/forums/viewtopic.php?p=1071361 Following on from my previous thread above the Vaillant engineer has just been. He said British Gas were lying and just using scare tactics and the boiler is fine! He said he replaced one part a sealing gasket and everything else is...
  7. N

    Need Urgent Help ... Boiler Condemned

    We applied for British Gas Homecare and the inspection was today. British Gas have disconnected our boiler - Vaillant ecoMAX 635. The boiler is just over two years old. They said the heat exchanger is leaking and it has also damaged / burnt other parts. They said Vaillant know about this...
  8. N

    Redirect condensing boiler steam?

    Our boiler is in the garage on the back wall. It is a Valiant condensing boiler. There is a vent on the outside wall of the garage, just above where the boiler is inside, from where the steam from the boiler exits. It is already at the highest position possible. The garden is to the side and...
  9. N

    Valliant Pressure Relief Valve Stuck Open - Urgent Help

    Our Valliant Ecomax 600 PRV is stuck open. I cant fill the system. Does anyone here work in West London - Ealing and can come round and sort this out for me by tomorrow midday? Please PM me the cost. Is there anything I can try? I am at the hospital tomorrow after midday so really need...
  10. N

    Eurosec Alarm Expansion

    We have a Eurosec CP8 wired alarm installed. Is it possible to add a wireless add on to the current system so a wireless door contact and pir can be added to the system? What parts would be needed? Thanks.
  11. N

    How do you change the bulb?

    http://www.aurora.eu.com/ProductPages/LampProductDetails.aspx?g=3000&c=88&b=18&oc=375 Does anyone know how to open the fitting above to change the bulb? The PDF manual on the site doesnt say how to do it. Thank you.
  12. N

    Problem with Kitchen Electrics ...

    Last year the house underwent a full refurbishment and the whole house was rewired. Passed all the tests and we got an electrical certificate - Domestic Electrical Installation Certificate DCM2. In the kitchen they installed the panel in the picture below for the appliances. There is a switch...