  1. spudkey

    Is 15mm Sufficient for Flow and Return

    Absolute rubbish 8kw of rads with a DT of 20deg requires about 0.35 m3/hr in 15mm this will give a velocity of 0.55m/s and a head loss of approx 2.7m per 100m !! please tell me why 15mm is incorrect if there is enough residual pump head in the boiler ?
  2. spudkey

    3 Phase current

    Just got a new compressor and its 3 Phase im trying to work out cable size, motor data plate says 15kw 29A so with 3 phase is the 29A per phase or split across the 3 (9.6A)
  3. spudkey

    Natural (mains) Gas pipe into the garden

    I've been given a gas fired tandoor from a disused Indian resturaunt that I will be piping up in the garden Roll on summer keema kebabs & nan breed
  4. spudkey

    Checking combi boiler gas consumption is correct.

    Run it at max for 2mins should do about 0.1 m3
  5. spudkey

    Valve Tags

    Trafolyte is the plastic, not really an on site job you need something like this http://www.ukengravingservices.co.uk/engraving-machines/xenetech-912-engraving-machine
  6. spudkey

    Gas Meter Fixing

    The point I'm making is if there is less than the allowed pressure drop across the pipework then there is no need for a 1" meter union Surely you didn't fit a u16 just because you needed 35mm pipework with a demand of less than 6m3 Didn't someone just mention the industry being full of...
  7. spudkey

    Gas Meter Fixing

    Yes can see that, so what would it need for 35mm ?
  8. spudkey

    Gas Meter Fixing

    Why should it be 1" x 28mm !!!!
  9. spudkey

    U16 Gas Meter

    A U16 meter will supply 16 M3/hour of gas, that equals approx 172KW
  10. spudkey

    Connecting to old 1inch copper

    [/url] right im getting back to you !! :shock: this post is about pipe sizes not converting measurements imperial pipe is measured ID metric is OD !! 1/2" and 15mm 1" and 28mm 2" and 54mm will all fit :shock:
  11. spudkey

    Connecting to old 1inch copper

    it will not be sloppy it will be tight 1" is slighly bigger 28mm fitting will go with a bit of force Ive never needed to use an adaptor !
  12. spudkey

    How much energy down a 32mm pipe?

    depends on the tempreture drop required across flow & return
  13. Untitled

    Untitled

  14. spudkey

    How Many of You..

    No, its new builds and change of use of building !
  15. spudkey

    How Many of You..

    Never, thought it was new builds and change of use
  16. spudkey

    Gas boiler KW question

    Proves what a joke the acs system and most assesment centers are
  17. spudkey

    Which of these boilers would you recommend?

    then get an Intergas or atag that is right for your house and get a heating engineer not a builder to sort it out !!!
  18. spudkey

    Lighting maximum

    Right I'll try again because all I've learnt from some idiot on here so far is that 1380w is enough and I don't need 2,2kw !!! Can someone please explain why I can't upgrade MCB to 10a