  1. L

    Bi folding doors instillation

    I could do with some help, we got a company to install some bi folding doors in my mothers house paid 25% deposit upfront, they then messed her around before the instillation saying they would install the windows on a certain date, to then cancel saying there was problems with the...
  2. L

    PFC question for 2391 exam

    doing revision for 2391 exam and i cant seem to find the answer to a question, would appriciate any help, i may just be missing the obvious here. :x state under what circumstances is it unnecessary to carry out a prospective fault current test at each sub-main distribution board on a...
  3. L

    Condensation in loft - Damp issue? or sumthing else?

    okay I moved into my first house about 2 years ago now, and the house is a small 2 bedroom semi detached 11 years old, last winter when I went into the loft I noticed water droplets all over the loft roof and didn't really think anything off it and I'm sure I went up in the summer there was no...
  4. L

    30 amp rewirable fuse feeding radial with 4mm cable

    possible to spur of this and im guessing u would have to spur off using 4mm cable, is there a limit on spurs? can u spur 2 sockets in series off a socket.
  5. L

    help needed and soonish :)

    hey people, Ive got my c&g 2391 test and inspection exam at 1 today, im all ready to go except im confusses about one thing. Continuity of ring final circuit condutors When carrying out step 3 which is connecting the live (line) and the cpcs together on a ring main to carry out the figure...
  6. L

    Running cable under tiled floor?

    Is it allowed to run cable under a tiled floor?if so what are the options on protecting the cable, A kitchen has a work unit in the center of the kitchen and a spur off the ring is needed in the unit to run a small fridge, other than running it down some sort of pole from the roof to the unit...
  7. L

    Price of a new combi boiler?

    well my combi boiler was condemed previously a vokera linea 24, and just started to get quotes, anyways got british gas out first and they quoted me 3k!!. cheapest 1.5k which is a whouster 24 like? spelling prob wrong lol.
  8. L

    linea 24

    still waiting for sum one to come see my boiler, anyways pressure loss is one of my problems, boiler been off a few bays now, i put 1 bar in to see if i lost it, if i had aleak but couldnt see it. would i lose this pressure even though the boiler hasnt been running. if anything i seem to be...
  9. L

    Pressure gauge faulty?

    currently awaiting sumone to come out to see my boiler which is looking like friday! anyways just though id put this question across? the boiler being a volkera linea 24, i have problems with pressure loss, still not sure whats the cause, now i was loosing pressure over a few days from what i...
  10. L

    vokera linea 24 few problems with PICS!

    okay these are my problems, wanna see if i can do any repairs b4 caling sumone out, had the day off to look at my combi boiler, moved into house a month ago.the boiler must be as old as the house 7 years old, the problem was i was losing pressure, checked for leaks and no signs of leaks, also...
  11. L

    voker linea 24, filling loop question with pic

    okay having a good few problems with my boiler but first i've lost pressure and have to re-pressure the system now the instructions say about putting in filling loop, open the iscolating valve ( which i cant find ) move the filling valve into fill until u get the desired pressure then move the...