    Vaillant home system boiler - hot water only mode.

    Hi Guys So its a new build house (frowns lol) - moved in last year, just realised when I switch the boiler to hot-water mode only using mode on the boiler. You can see the valve moving upstairs but the boiler will not fire up. In both heating and hot-water mode, all works fine. The guys from...
  2. A

    new build house external render damage with car

    Hi So we have a new build under 2 years old now, unfortunately my father in law reversed into the corner and of course a small chunk of both sides and the render corner, have been damaged. Is this an easy fix with some render mix like this ->...
  3. A

    Pyronix enforcer PIR going off when exiting house

    hi guys after 5 months of no issues with my Pyronix enforcer, randomly the other day both on enter and then today on exit the PIR in the hall (set as Entry Route as I only have one area set as A) went off when I set alarm via the panel and open/closed the door (Final Door) Set up as follows...
  4. A

    Pyronix Enforcer v10 - Set Fail Warning

    Hi Just wanted to know what this 'Set Fail Warning' setting is referring to (as opposed to Set Fail Timer which is set at 40 secs default. In the manual it states "Time for which a set fail warning will be present." Yet it seems to be set at 0 secs as default, what does this option do...
  5. A

    Yale SmartHome Alarm with GSM

    Hi guys Fitted this myself the other day with 2 x PIR and 2 x Door contacts - all working well. Then powered down system and fitted a Vodafone payg SIM card . I can dial in and both Arm and Disarm the system. But it will not allow me to remote command via SMS nothing happens even after setting...
  6. A

    Honeywell DT90E - how to wire up?

    Have a ariston boiler system boiler. Drayton RTS1 room stat and a drayton Lifestyle LP112 programmer. I want to replace the RTS1 with the honeywell DT90E - I believe the system uses a neutral to switch @240 mains also in conjunction with this lifestyle timer. So do I need all 3 wires to...
  7. A

    Ariston condensing system boilder CH pump overrun

    Hi I have a Ariston microGenus 27 system boiler (condensing) Separate Room stat (simple drayton analogue) Seperate timer. This is a new issue I have not seen before 1. CH and HW set for morning, room temp on stat set at 23c 2. Boiler runs fine for 30mins 3. CH pump overrrun keeps...
  8. A

    Ariston Genus HE 24 Combi - DHW pump overrun issue

    As above Ariston Genus HE 24 - CH works all fine. DHW - set to 50 degrees. Run shower at full pace - will run fine for first few mins then... the DHW pump overrun kicks in every min or so resulting in a few seconds of a colder shower (like a constant cycle of boiler firing on and off)...
  9. A

    WC in garage conversion

    Do i require a soil pipe vent of some sort if installing a WC in the garage to a main soill junction to the house (2 inlets, 1 oulet) the garage is circa 15 m away. the drop would be about 1:40 ratio. TIA
  10. A

    Triton Dover Manual Mixer Shower HW/CW wrong way around

    just purchased this from http://www.screwfix.com/prods/89417/Bathrooms/Showers/Mixer-Showers/Manual-Showers/Triton-Dover-Manual-Mixer-Shower and all pipework has been done behind tiling. Just realised the hot and cold water feed are the wrong way around, now I realise this poses a safety...
  11. A

    WC, Sink and Shower drainage from Annex behind house

    Warm Hello to everyone, I am a newbie just looking for some general advice. I have had an annex built at the rear of my house with a WC, Shower and sink waste connections all connected in the following configuration. (please excuse use of terms and correct as necessary) 1. Main brown soil...