Recent content by 30nine

  1. 3

    Weird Kitchen circuit

    Hi Securespark, No It's just a 13A single socket on the ring.
  2. 3

    Weird Kitchen circuit

    Thanks for the correction EFLImpudence. Thanks rsgaz, I'm going with the MK FCU idea you mentioned earlier, but keeping it as a 2.5mm ring, mainly because I have like, 30 odd meters laying around plus I think the walls need plastering regardless. I'm just seeing it as an extension with an FCU...
  3. 3

    Weird Kitchen circuit

    OK that's great, thanks for your help and time.
  4. 3

    Weird Kitchen circuit

    Thanks, Yep will do. Well there's other sockets on the other walls coming off a different ring for fridge and freezer plus sockets above worktop under window, so the kitchen in total will have 8 double sockets. The only thing I forgot to mention is the socket for the microwave and kettle is...
  5. 3

    Weird Kitchen circuit

    Ok, Iv'e had a word and attached a rough diagram of what I want to do. Move the current JB up near ceiling level and change to FCU or newer JB that can supply the cooker hood and bury the cable whats above worktop level in plaster. Would be a good idea but trying to get away with just the...
  6. 3

    Weird Kitchen circuit

    Yes, I'll have a word with her when she gets back from work and see what she wants to do with the wall units and post a diagram then. Thanks to both for your help so far.
  7. 3

    Weird Kitchen circuit

    Thanks, I'll have a look again to see what she wants to do with the wall units. No I won't bury the junction box.
  8. 3

    Weird Kitchen circuit

    Thanks for the reply, Lollipop :D. Ideally I would of liked to keep the ring in 2.5mm (have quite a bit :)) But yeah if you think it would be better as a 4mm radial, then that's ok too. Regarding the junction box, I was going to put a newer connection box somewhere up near the Hood, not to...
  9. 3

    Weird Kitchen circuit

    Hi, Just installing and moving some kitchen units and have discovered that the normal way of wiring that I have seen in our previous house (Ring or radial) is different. A 2.5mm ring seems to have been taken from an old cooker control unit, now a round JB to form a ring to the sockets. Looks...
  10. 3

    Loft Conversion Project

    Looks real good..nice windows, great floor.
  11. 3

    Newel Post Fitting and stringer (Pics)

    Any ideas my friends? :)
  12. 3

    Newel Post Fitting and stringer (Pics)

    Hi All, I Need some advice on how to fit the bottom newel base, as there was not an existing post in place. I want to cut the stringer ;level with the first riser, however I have cut a 3" piece out of the end of the stringer to check if it was bolted in and it seems to go in to the...
  13. 3

    Outside cable.

    Ive just seen one! :shock:
  14. 3

    Moving socket 2 feet

    What inspection ? :?: