Recent content by Abcplumb

  1. Abcplumb

    Problem with British Gas Boiler RD1

    Thanks guys this really helped out today. After an hour trying to figure out this intermittent fault, I tried a quick search online which helped me out big time. A Good Friday wasn't going so good until I crunched the sensor. Just want to add this works!! Had to do Something as everything...
  2. Abcplumb

    How to keep Ferrnox LS-X Leak sealer from drying out?

    I do agree, BG do abuse is tube. But it does have its uses. I don't use it that much, may be that's why it always dries out before I need it again.
  3. Abcplumb

    How to keep Ferrnox LS-X Leak sealer from drying out?

    Sounds like someone has had a bad experience with it.. :lol:
  4. Abcplumb

    How to keep Ferrnox LS-X Leak sealer from drying out?

    How do you guys keep the LS-X from drying out. This tube is very handy, but expensive as it always dries out before I can finish it. I've tried carefully tightening the cap, but some parts at the top always dry out. Any recommendations on how to prevent this from drying out. [/b]
  5. Abcplumb

    Glowworm 24cxi error code F3

    Tony No I was not aware of the rules. I have now registered myself to the Gas Safe Club on this forum. I am waiting to be approved. I wouldn't even encourage Gas Safe engineers who are not confident in repairing boilers. As I believe diagnosing and repairing is a skill which requires...
  6. Abcplumb

    Glowworm 24cxi error code F3

    Yes Agile I know that :roll: If you're suggestion I'm a DIY'er I'm not. I have been Gas Safe for the past 8 years. I prefer to be sure when diagnosing rather then trial and error. I've read lots of posts by you, clearly you are a very knowledgeable man when it come to heating, but I...
  7. Abcplumb

    Which Filter (including location guide)

    So which one did you go for then? I always use the ManaClean Proffessional 2, more for the easy of installation then for its protection aspect. I'm not to impressed with it tho, looking to fit another type of fitter which gives better protection on all my installs now. Still deciding if I...
  8. Abcplumb

    Glowworm 24cxi error code F3

    Had the same fault today. 1st visit no display, after replacing the pcb, I'm getting a F3 fault now Tested the fan plug blue & red and there is 24v then it drops. Am I right in thinking the pcb only sends little bursts of 24v Just like the initial start up on the DV motor on a vaillant...
  9. Abcplumb

    Eco Tec 824 hot water mystery

    Never tried running the pump on a drained system :?: I didn't clean the hoses as the magnaclean only had very little sludge on it, and the filter was also clean. I did press the hoses and the were NOT firm like the once which have sludge in it. But I do agree I should have done the...
  10. Abcplumb

    Eco Tec 824 hot water mystery

    Turned out to be a weak pump. Replaced the wilo pump to a new grundfos pump and all is good. I was also told by Vaillant technicals that there isn't a way of confirming its the pump. All 4 NTC's where fine. Flow rate was around 6.
  11. Abcplumb

    Eco Tec 824 hot water mystery

    Thanks 831Bunny The DV is good, even after running the hot water the heating pipes didn't heat up. I'm suspecting the NTC, but will check the temperature differential between the flow and return and the ohms It's hard to image a blockage issue as the dhw plate was very clean.
  12. Abcplumb

    Eco Tec 824 hot water mystery

    Why should you help.......aammmm maybe coz you're a nice guy and like sharing your knowledge? I thought you may suggest a smart way of testing it through the diagnosis menu. Anyway I appreciate you pointing me in the right direction.
  13. Abcplumb

    Eco Tec 824 hot water mystery

    Nope, I thought if it was a NTC fault I would have got a fault code. I'll be going back there tomorrow. How would you suggest I test the NTC?
  14. Abcplumb

    Biasi m90 24s

    Those biasi pcb's are too expensive. There is a company in wembley that repairs pcb's and gives a years warranty. You send them the faulty one and they send you a reconditioned one.
  15. Abcplumb

    Eco Tec 824 hot water mystery

    Hi guys Need some help pls. The above boiler has a hot water issue, ch working perfectly fine. When you turn the dhw tap on the hot water works fine for about 5mins then it suddenly starts to drop. I had the dial set to 57c, the hot would come on and go to around 70c then drop to...