Recent content by agb32

  1. A

    Baxi duo tec he24 CH but no hot water, no error code

    Hi all, Changed the DHW NTC, and indeed - that has fixed it, so thanks a lot, and sorry for my doubt... I've made a donation to Donnas Dream house as suggested on another forum, since it saved me a fair packet for a new PCB, and someone to fit it, that the Baxi helpline had recommended. If...
  2. A

    Baxi duo tec he24 CH but no hot water, no error code

    By thermister, I presume you mean this: http://www.plumbcenter.co.uk/en/heating-parts/domestic-boiler-parts/baxi-5114725-ntc-sensor-34608
  3. A

    Baxi duo tec he24 CH but no hot water, no error code

    ok - I'll try changing the NTC... and post back if it works... I suppose I've been reluctant because I can't understand why it should work (and I like to understand something before I do it!)!
  4. A

    Baxi duo tec he24 CH but no hot water, no error code

    Hi, I assumed that because the resistance measurement is okay and because the temperature measurement given is sensible, then the DHW NTC sensor isn't at fault. But - maybe my assumptions are wrong? Have you come across this problem before? If it was at fault then it should give the E50...
  5. A

    Baxi duo tec he24 CH but no hot water, no error code

    The pipes are getting hot in CH mode (when the boiler is firing), but not getting hot in DHW mode (because the boiler doesn't fire). Temperature readings from the CH NTC are what I expect them to be. By working fine, I mean that heat is getting to radiators at the correct temperature when it...
  6. A

    Baxi duo tec he24 CH but no hot water, no error code

    Hi, I have a baxi duo-tec he24 which is causing some puzzlement at the moment. Central heating is working fine. But direct hot water is not working. When I turn the tap on - the Hall effect sensor works (red LED). The indicator on the front panel indicating that it recognises water is being...
Back