    Ideal Icos m3080 fuse blowing

    I have a similar sounding problem on my Ideal Response 120 - Ideal have told me it's most likley to be the low water pressure switch that needs replacing. (There's a thread posted on here under the title "Ideal Response 120 ...fuse keeps blowing" that you may find useful Alex
  2. A

    Ideal Response 120 Boiler ...keeps blowing fuses

    I looked for any sign of leakage around the LP switch and couldn't see anything. When I had the front open I noticed that the neon indicator for "Mains on" had blackened the surrounding area, and looked "burnt out" although it still functioned. I isolated the indicator and the boiler worked...
  3. A

    Ideal Response 120 Boiler ...keeps blowing fuses

    Just spoke to Ideal (after a lengthy hold!)... Seems like a bit of a "classic" problem - the low water pressure switch needs replacing. Has anyone had any experience of doing this or know how much this kind of job is likely to cost??? Alex
  4. A

    Ideal Response 120 Boiler ...keeps blowing fuses

    The heat exchange is OK (I've heard of the cracking problems but it's bone dry inside) - I've got the manufacturer coming out in January (earliest they could do!) to fit the overheat trip swich that should extend the life of the h/e. Pump appears fine.... Alex
  5. A

    Ideal Response 120 Boiler ...keeps blowing fuses

    I have a 4 year old Ideal "response 120" combi boiler that began blowing fuses yesterday morning... The 3Amp fuse blows, I replace it, the system is fine for anything between 5 minutes and a few hours and then it blows again. Both DHW and central heating run OK when the system is working...