  1. A

    Worcester Bosch Danesmoor 20/25 - locking out

    Boiler now running fine with new coil - thanks again
  2. A

    Worcester Bosch Danesmoor 20/25 - locking out

    Checked resistance this morning when cold = 2076 ohms Ran boiler to lockout (about 4 minutes) resistance = open circuit After about 5 minutes resistance = 2096 Picking up a new coil now. Thanks oilman :D
  3. A

    Worcester Bosch Danesmoor 20/25 - locking out

    Thanks oilman - will check the coil resistance. All oil filters are clean (external, oil pump and nozzle) - just cleaned them (although they weren't dirty). Photocell was clean as well but I cleaned it anyway.
  4. A

    Worcester Bosch Danesmoor 20/25 - locking out

    Thanks for replying. The burner is locking out.
  5. A

    Worcester Bosch Danesmoor 20/25 - locking out

    My boiler has just started locking out and I am hoping for some advice. Burner is Electro Oil Inter B11C with conventional flue, oil tank above boiler, single line to Danfoss BFP 11 pump. The boiler has run from new faultlessly for 5 years. System is Honeywell S plan, sealed. I have...