    Worcester junior 24i and Nest thermostat

    L and N on the heatlink should have constant power. I’ve connected it to a power outlet. Ls to common port number 2 on the heatlink. Lr to call for heat port number 3 on the heatlink. And don't forget to remover the bridge that connects Ls to Lr.
  2. B

    Worcester junior 24i and Nest thermostat

    I've just finished installing and i'am happy to say it works just fine :-)
  3. B

    Worcester junior 24i and Nest thermostat

    hi all, I have a Worcester junior 24i combination boiler. At this moment there is no room thermostat installed. To make my life a bit more convenient i would like to install a Nest thermostat. Is there anyone at this forum that has some experience with this? Is the boiler compatible with the...