Recent content by combiman1

  1. C

    Baxi 105e instant Problem !?

    Hi Chumley as the problem is common between H water and C htg it would point towards the Air pressure switch faulty when the boiler starts the Fan puts pressure down the positive pressure pipe and flicks the air pressure switch over and then the burner lights however if this switch closes again...
  2. C

    thank you libby lou lou it was my first post on here and thanks for your thanks if you know what...

    thank you libby lou lou it was my first post on here and thanks for your thanks if you know what i mean ha ha best regards combiman1
  3. C

    Ferroli Optima 701 intermittent DHW

    Hi karlitop glad my advice helped you regards combiman1
  4. C

    3 band A combis needed wheres Best price Anyone?

    Hi adamneve i have fitted the IDEAL LOGIC plus this has 5 years parts and labour guarantee also until the end of march worcester-bosch are giving 5 years parts and labour with all of their combis ideal logic + availiable in 24 kw 30 kw and 35 kw outputs hope this info helps regards...
  5. C

    Ferroli Optima 701 intermittent DHW

    Hi Karlitop just read your posting re ferolli optima 701 you say that the Central heating sensor and the limit sensor has been changed BUT DID HE CHANGE THE HOT WATER TEMPERATURE THERMISTOR ? on the 701 there are 2 temp thermistors 1 for c/heating and 1 for hot water the symptoms you describe...