Recent content by dib79

  1. D

    New Sink fitted Waste Pipes Leaking

    never had problem with mcalpine 1 1/2 bowl sets,get the lad that fitted sink back if i was you,only need rubber washers no sealant
  2. D

    mira 88 shower

    thanks very much for your help, you have saved me a lot of messing around,i was going to pull it to bits and look at it for him,i'll just fit new mixer for him now instead
  3. D

    mira 88 shower

    thanks for quick reply,have neighbour who has same shower as me and since he changed to a combi the cold supply doesnt shut off properly and keeps running from shower head he has replaced seal but still has same problem is this because shower is not designed for combi or does seal just need...
  4. D

    mira 88 shower

    is a mira 88 mixer shower suitable for use with a combi boiler?mixer was originally tank fed but obviously wont be if we change to a combi,just wondered if we needed to change mixer.thanks in advance
  5. D

    vola kitchen mixer

    thanks for your reply,have found out how to remove spout now,180 degree turn and pull.
  6. D

    vola kitchen mixer

    anyone know how to remove spout on vola kitchen mixer?there is no grub screw, the o rings need replacing but cant get spout out.
  7. D

    Replacing cloak room toilet and basin?

    you may not have to drain tanks in loft,should be valves fitted to turn supply from tanks off,should be red wheel/lever
  8. D

    size of cistern for shower

    i am fitting a new shower for ensuite,i have a 900/400 hot cylinder which will be supplied by cistern in loft just for this,no other outlets im hoping i'll have enough head so no need for pump,just wanted to know if i had to have 50 gallon tank or would 40 do,i may have to fit shower pump if...
  9. D

    vent pipe position

    thanks for reply,i know this way is not ideal but there really is no other way just wanted to know if it was possible,will pull bends instead of joints and hope its ok.kind regards
  10. D

    vent pipe position

    i'm fitting hot water cylinder for new bathroom,the cwsc is not directly above it,is it ok to for vent pipe to go through ceiling then across loft about a metre before going up and over cistern.the cwsc is in middle of roof to allow it to be raised but vent pipe would come through at edge of...
  11. D

    size of cwsc

    thanks for reply,im limited for space as there is no loft to put tank in,the main bathroom has cylinder under cwsc in a big cupboard,high ceilings so room to sit cwsc high enough on specially made frame,the bathroom is long way from bedroom where ensuite is to go so i want to recreate this...
  12. D

    size of cwsc

    hi all ,is a 25 gallon cwsc big enough to supply hot cylinder 36/18 and cold feed to shower,hot cylinder is just for shower too so no other outlets,would need small pump for shower as not enough head without one
  13. D

    water softener needs sterilising?

    anyone know how to sterilise a water softener thats been out of use for about a year,was not used due to flexis being kinked and leaking. have replaced and now want to get softener going again..
  14. D

    series 155 water conditioner

    hi all,can anybody tell me if it is ok to connect a series 155 water softener using copper instead of flexi pipes,the flexi pipes that are on it at the minute are too long and have been twisted and leak .If i can connect with copper pipe it will save me finding flexi's that are short enough...
  15. D

    grit in sink

    hi all,just ran mixer tap in friends house and when water had drained away it left what looked like a shovel full of sand in sink!tap has not been used much for 4 or 5 weeks prior 2 me using it,could this be a problem with water softener?will it clear with regular use or get worse?any ideas
Back
Top