Recent content by eltommos

  1. E

    Flat roof drip edge replacement

    Hi Catlad - What would you use as a filler?
  2. E

    Flat roof drip edge replacement

    Hi Catlad - many thanks for your reply. I won’t start this job until the weather warms up some time next year. I don’t have any leaks just want to get rid of pooling which is more visible this time of year so it can wait until then
  3. E

    Flat roof drip edge replacement

    I would use a circular saw to cut through the fibreglass and OSB at the 12'' joint line (but not through the joists) 1 - Remove existing 12'' OSB / fibreglass 2 - Add new 12'' OSB and new drip profile 3 - Sand down existing fibreglass at 12'' joint line 4 - Apply fibreglass joining tape at...
  4. E

    Flat roof drip edge replacement

    Hi Catlad - could you let me know reasons why you wouldn't do that?
  5. E

    Flat roof drip edge replacement

    Would welcome some advice - I'm planning to replace my fibreglass flat roof drip edge and around 12'' of OSB board as over the last 10 years water has started to pool and not completely drain into the gutter. It looks like the OSB board has warped and curled upwards at the drip edge causing...
  6. E

    How to fix decking to fibreglass flat roof

    Hi all - I successfully managed to install a stainless steel and glass balcony (around 10 years now) including decking on to my flat GRP roof. I had planning permission plus building reg approval. I bolted the stainless steel tubular frame structure onto wooden beams (aprrox cross section 5''...
  7. E

    How to turn off new type outside water mains stoptap

    Rotated about 3 full turns and water is now off - many thanks
  8. E

    How to turn off new type outside water mains stoptap

    it rotates more than 90 degrees it turns a number of times clockwise.
  9. E

    How to turn off new type outside water mains stoptap

    To turn off new type outside mains water stop tap - is it just a case of turning clockwise until it tightens up? It's a plastic round fitting which rotates both clockwise and anti-clockwise and sited next to a hexagonal fitting.
  10. E

    Whirlpool Dishwasher - Where can I get a Rubber Hose

    Whirlpool Dishwasher approx 7 years old model DWF B10.Short length rubber hose connected to the circulation pump has split. This hose is moulded on to the plastic pump housing. Is it possible to buy just the hose. It' around 40mm long by approx 27mm diameter.
  11. E

    Pointing falling out - can I ask builder to fix it?

    Hope someone can advise. Added an extension on the house 4 years ago. New bedroom above garage. Pointing between concrete roof tiles and plastic gulley panel has all fallen out. Is it reasonable for me to ask the builder to come back and fix this without charge? The builder is FMB member but I...
  12. E

    How to fix decking to fibreglass flat roof

    Many thanks, Freddymercurystwin, for your reply. I do have full planning approval. The flat roof construction is a recent extension. The roof joists are 200mm at 450mm centres with 25mm plywood on top. I think gluing down with fibre glass is a good idea - I've seen this before. The balustrade...
  13. E

    How to fix decking to fibreglass flat roof

    Hope someone can offer help with this one. I want to lay a 3m x 5m wooden decking on top of fibreglass flat roof. I don't want to drill holes through the fibreglass flat roof because of potential water leaks. I'm thinking of gluing the decking joists directly on to of the fibreglass. I could...
  14. E

    Radiator heats ups when hot water only is on

    OK thanks - I will try switching on and off. Pump speed not turned or changed. Where would the MV be? Is this short for Main Valve?
  15. E

    Radiator heats ups when hot water only is on

    I don't have details of the complete layout. All I can say is that it's only started happening 2 days ago and it was ok before, even after the changes made. Any other ideas would be appreciated. :oops: :oops:
Back