Cheers guys, the plastic approach seems like the easy option, but I'll sleep on this one and may have a crack at the copper bending if I've got the time.
There's no instructions regarding the union elbow at all - only fitting the rise rail itself. It looks like this: .
Any tips on how...
Thanks Stem/Bathstyle,
It seems to be a different shower to the Aqualisa Axis.
I considered turning the valve "upside down", but the temperature and flow numbers/graphics on the cover plate would be upside down too.
I guess I'll just have to route the pipework round and down below the...
I have just bought an Axis Mixer Shower set with concealed valve from B &Q.
The shower head is on an adjustable riser rail, and i would normally expect to locate the wall union elbow directly below the valve controls. HOWEVER, the outlet for the valve heads upwards (as if to a built in...
Thanks Dave, I see you're actually in Norwich like me - what are you under in the Yellow Pages?
I've left a message with my usual engineers and I'll ensure they give it a full service as well bu will keep you details in mind. The unit's probably been in the property for around 11 years...
Thanks for the response Dave,
Checking my paperwork the last full service we had was 2 years ago. Having said that I would have expected the boiler to be fit for purpose for a good while after replacing something major like the heat exchanger (and spending £200+)?
If not, I guess I...
Hi there, i have a Vokera maxin 28e and it has started playing up over the last week or so.
For CH the furnace cuts out before hitting the room thermostat temperature. I have now turned the temperature control on the boiler to the maximum amount which delays the cut out, but the boiler seems...
Thanks for the replies,
Ideally I want use TRVs to control the tempreature in the rooms more specifically. One of the rooms is my baby's nursery and we want to be able to keep it at the right temperature.
I will take a picture but it might take me a while to figure out how to post it...
Hi,
I'm replacing a couple of radiators in my house and would like to install TRVs. I'm not skilled enough (or don't want to go to the trouble of!) altering pipework.
The TRVs that I've seen appear to be too long horizontally. The non thermo valve I'm taking off simply has a large nut on...
Hi Noseall,
We've got drywalls throughout the house, the one i was working on last is just a thin partition wall between downstairs loo and stairs - it's about 14cm thick.
The house was originally part of a Victorian pub and all the other walls have been plasterboarded over.
I've had a...
Hi,
I'm starting to replace skirting board throughout our new house. The plasterboard walls appear to have been fixed by Dot and Dab method.
I was aiming to use nylon drywall screw in fixings but when I screw them in to the plasterboard they go so far before hitting an obstacle, and start...