Recent content by gaz6699

  1. G

    Central heating back boiler problem Cant refill system !

    Thanks for the suggestions I thought this was most likely the case now just got to try and find the blockage that should be fun ! as soon as i saw the tank over flowing in to house tank i knew it was wrong an it will be changes as soon as possibale until then i aint drinking the water !
  2. G

    Central heating back boiler problem Cant refill system !

    I have just moved in to a new house and hove problems with the central heating radiators eiher didn't work or worked very badly central heating is run off a backboiler from living room fire i have taken all the radiators off and cleaned loads of thick black sludge out of them and all...
  3. G

    Philco WM1000 trips RCD

    there was a a light leek throught the electrical connections of the heater element that was causeing a slight short to earth on the nutral side orderd a replacment eliment which should now fix the problem
  4. G

    Philco WM1000 trips RCD

    I have a Philco wm1000 that keeps triping the RCD (earth leakage breaker) i have had the machine apart and cant find any leak or damaged cable we have had this problem for a while it took a month or so just to trace the problem to the kitchen as it dosent happen every time we use the washer i...
  5. G

    Philco wm1000se drum dosent spin

    now Fixed turned out it was the brush on the motor got some brushes off a whirlpool that where the same model no but the brushes are a slighlty difrent size and had to be filed down to fit the cartridge for the philco as the monting angle was oposite way round to mine but now all working
  6. G

    Philco wm1000se drum dosent spin

    i have a Philco wm1000se it goes through all the motions fills drains and goes through the various programs but wont spin the belt is fine i am unsure as to if the problem is with the motor or the controller. with a volt meter if i spin the motor it does show a small voltage (500ma with no...