Recent content by HKB

  1. H

    Potterton boiler control

    I appreciate this is an old thread, but someone may find this helpful. Fan cycling is likely caused by a fault in the -50V low voltage power supply on the 407677 PCB (located just to the right of relay 1), which energises relay 1, and relay 1 keeps the fan running after the air pressure switch...
  2. H

    Drayton Wiser and Vaillant Boiler

    Not sure why, but it is overshooting by 0.5C. Today it was calling for heat at one point even though measuring 20.5C with a set point of 20C. I hope it will settle down but I don’t know how adaptive or sophisticated the software is.
  3. H

    Drayton Wiser and Vaillant Boiler

    So far only one room thermostat in a central downstairs location. The ground floor is semi-open-plan. I’ve started cautiously. I may buy radiator stats later for some bedrooms.
  4. H

    Drayton Wiser and Vaillant Boiler

    Thanks. I haven’t counted. But the oil setting is a lot less intrusive. It seems to overshoot a little more, but only by 0.5C which is a small price to pay for a quiet life (and perhaps more efficient gas usage on an old boiler). I’ll never know because it’s not a controlled experiment. I would...
  5. H

    Drayton Wiser and Vaillant Boiler

    My 24 year old Potterton boiler was short cycling after installing the Wiser system. It sometimes fires up and the pump runs for only a few seconds. It also boils up and I suspect short pump times may not help, but this may be unrelated. I initially suspected the overrun thermostat was...