    LED strips on lighting circuit

    Hi, I use similar ELG-100 24v PSU's to drive LED's in my house and although lower power than yours the spec sheet recommends a max of 3 PSU's on a 16A type B breaker or 6 on a 16A type C. For your XLG-150 they recommend a similar 16A breaker with a max of 4 PSU's on a type B or 8 on a type C...
  2. I

    Low voltage wiring for domestic LED installation

    I am wiring an extension, all work being done under BC and am planning on using 4 LED uplighters to illuminate a 4 x 3.5m room via its vaulted ceiling. The LED's I have are max 32V @700mA constant current devices and the drivers I have are 24V DC input DC-DC converters whose worst case open...
  3. I

    Replacement Window inset distance

    I am about to order replacement windows for entire property as part of a larger set of building works including a 2 storey extension. I have decided on Velfac units and since my house is rendered their recommendation is to render first and fit the windows after. Their instructions show the...
  4. I

    Electricity supply through loft

    Thanks for the replies Ban -appreciate anything up to the meter is DNO territory, I really was trying to establish if continuing to supply via the loft was acceptable as it seems to me an unnecessary potential fire risk. Appreciate that I need to get a quote from the DNO if I want the main...
  5. I

    Electricity supply through loft

    I have a 1940's property whose existing supply is overhead, entering the roof/loft on one side, traversing the width of the house, exiting other wall and is clipped onto the rendering dropping down to 4ft and entering wall to the main fuse/FCU. I have planning permission for an extension on the...
  6. I

    Leaking sealant around cutout

    As a kid (some 50 odd years ago) I remember seeing in the Science museum a large glass conical funnel into which a cube of tar had been placed, presumably some time before I was born. When I visited it the tar had started to 'dribble' down the neck of the funnel, so I think that under the force...
  7. I

    Good old days

    I remember developing increasingly sophisticated ways to shock workmates at a certain electronics Co in Chelmsford when it was commonplace to store small electronic components in empty metal tobacco tins - we used to solder a small HV capacitor between lid and base, run some tape around the lid...
  8. I

    Power and Data in same conduit?

    Ricicle -I hadn't thought of doing it that way around I presume that burying SWA directly improves the heat conduction through direct conduction aptsys - that was where I was coming from, speed/reception is marginal and made worse by WPA2 and addtionaly by vpn. Cheers and thanks for your...
  9. I

    Power and Data in same conduit?

    holmslaw - I don't trust wi-fi - it can be hacked (I work in IT) - and those homeplugs are as far as I can tell only protected by 56bit DES, so I'd rather minimise risks and go wired :-)
  10. I

    Power and Data in same conduit?

    BAS - If I could reliably get hold of my electrician I would - but he's not answering his phone at present, and I forgot to ask him about the data cabling when he came around to do a survey.
  11. I

    Power and Data in same conduit?

    Paul -apologies for not clarifiying - the swa will be in a conduit buried to whatever is the required depth. BaS - I just was enquiring whether there are any reasons why it would not be safe to run the data cable in the same conduit or a separate one. Apart from possible emi interference I...
  12. I

    Power and Data in same conduit?

    I have an electrician running power using 10mm two core SWA to my shed some 50m distance from my house, and wondered whether it is permissible to run a Cat5 data cable in the same conduit? Cheers Ed
  13. I

    To glue or not?

    I live up the road from Brooks and concur their staff are very helpful and they also have impressive stocks of timber - I purchased some oak from them, told them I wasn't sure what variety and they listed 6 of their huge bays and allowed me to wander around to select what I wanted. Another...
  14. I

    Oil or preserver for cedar garden table?

    I would suggest that you use boiled linseed oil, thinned 50/50 with turpentine. Apply with a brush, leave for 30 mins -first coat will soak in pretty quickly and then wipe over with a cloth. Leave for 2-3 days and repeat, and repeat as many times as you like until you achieve the level of gloss...
  15. I

    Floor loading question

    I have a new built shed which I plan to use as a workshop and am looking to buy some new woodworking tools ;-) ..however some will be quite heavy - ~160kg or so on a base of 460 x 710mm. Question is this - my base is concrete piers with wood joists as per the picture below. Will this be...
Back
Top