Recent content by Jackuzi

  1. J

    Replacement bottle gully insert?

    Morning all, Sorry if this is a stupid question, can't seem to get an answer through googling. I have a bottle trap drainage gully in the garden and one of our little furry friends has chewed the insert. Can I buy one as a replacement? Thanks Glen
  2. J

    Lintel?

    I if go with putting in a 600 x 100 x 65 steel reinforced concrete lintel over the cut, can I cut the hole for the lintel first, get that in place then go ahead with cutting through for the flue under that? Can I disc cut the hole for the lintel to the same dimensions and then squeeze the...
  3. J

    Lintel?

    Thanks guys
  4. J

    Lintel?

    The second drawing shows the top down view of the route of the pipe from the wood burner in black pen. The other pipe route drawn in pencil is an alternative route but adds another offset which I'm trying to avoid. I'm not sure what you mean by a retaining lintel?
  5. J

    Lintel?

    Can anyone help on this please or point me in the direction of who I might ask?
  6. J

    Lintel?

    Hi all, I am planning to cut a hole in an internal load bearing wall to pass a new 8 inch (external) twin wall chimney flue through. I am passing this through on a 45 degree angle (both vertical and horizontal) and this is below a joist that has a small masonry wall above. I am thinking I...
  7. J

    Floor joist in the way

    AFAIK only that distance to combustibles should be no less than 50mm.
  8. J

    Floor joist in the way

    Oh didnt realise it would be that easy...so I could use something like Supalux sheet?
  9. J

    Floor joist in the way

    Hi all, I am trying to plan the route for a twin wall flue (for a woodburner) through my house. I have taken measurements, inspected under floorboards and have planned my desired route. The problem is I need to pass between 2 joists that are only 260mm apart. This doesn't give me enough...
  10. Untitled

    Untitled

  11. Wood burner

    Wood burner

  12. J

    Induction hob pulsating?

    We recently bought a Fagor IFF-4R hob and are experiencing a weird situation. When running the front and back zones together (left or right), they seem to cycle in turn eg front pan has heat for about 1 second then stops then back pan on 1 second then front etc. This means you cant maintain a...
  13. J

    No earth bonding to gas pipe

    Firstly, thanks for the reply. Secondly, apologies for the extra info, I thought of it 6 minutes after my initial post and did check I hadn't already had a reply so as to mess people about. We obviously posted at the same time. The property is only 11 years old and I am pretty sure the...
  14. J

    No earth bonding to gas pipe

    Added info to initial post.
  15. J

    No earth bonding to gas pipe

    Hi all, I am fitting a new kitchen and I'm having a new 10mm circuit to the new cooker/hob. This is going to replace the 6mm that is currently there and the MCB changed to a 40A one. My electrician checked for earth bonding and although the water is bonded the gas is not. Can someone please...