Recent content by Jakeh83

  1. Jakeh83

    Level block wall before cladding

    I'm putting stone z clad on my house front I've nocked the old render off but there's some big pits in the block, adhesive can be bed 15mm thick but some of the pits are deep, my question is can I create a flat sirface by filling with something first to flatten then apply adhesive on top?
  2. Jakeh83

    Cladding over lumpy render

    Hi, I'm looking at getting some stone cladding on the front of my house, its currently rendered with stones in it, can i adhesive the cladding straight on or should it be removed?
  3. Jakeh83

    Oil combi with electric unvented

    I have an unvented cylinder already from a job, it only has 2 elements and no coil. I was thinking of leaving the kitchen on the combi and putting the unvented on the bathrooms?
  4. Jakeh83

    Oil combi with electric unvented

    I have an oil combi 12/18 which doesn't really cut it for hot water having 2 bathrooms. Can i tee in an electric element only unvented to the hot supply? Or do i have to disconnect hot supply and leave one tap on boiler then pipe in unvented separately. Thanks
  5. Jakeh83

    Riello rdb burner

    I didn't want to go poking round insife the burner as its hard to access, I've traced it back to faulty 2 port, noise was pipes vibrating due to bypass
  6. Jakeh83

    Which part to replace? (Worcester heatslave 15/19)

    Its a riello rdb its not noisy all the time.
  7. Jakeh83

    Which part to replace? (Worcester heatslave 15/19)

    Hi I'm hoping for some help, i have the same sort of thudding sound when the boiler switches off now and then and my RCD had tripped a couple ofbtimes although this may be a coincidence, I've eliminated any water pump and valve issues but wondering if its a new motor needed. Regards
  8. Jakeh83

    Riello rdb burner

    Hi, i have Worcester greenstar heatslave 18 oil boiler, the last few nights the main rcb had tripped i reset and all fine but went off again overnight, could this be related to my burner randomly not firing? I'm gas safe so tested all components in the boiler ok only thing really is the burner...
  9. Jakeh83

    Insulating behind wood panelling

    I'd like to insulate anyway as it would be better right? what would be best to use?
  10. Jakeh83

    Insulating behind wood panelling

    Hello, im thinking of wood panelling my living room wall with reclaimed wood, should i insulate behind it beforehand preferably with the thinnest insulation, will this cause any condense/damp issues? Tia
  11. Jakeh83

    Self leveling floor

    Hi, i need to level a floor thats been concreted but its about 70mm deep, i dont want to use that much self leveling compound only about 3mm, whats best to fill some space above concrete apart from more concrete, can you make a homemade self leveling compound from sand and cement and then put...
  12. Jakeh83

    Loose neutral wire

    No an electrician did
  13. Jakeh83

    Loose neutral wire

    I could get my multi meter out but dont fancy taking all the sockets off the wall again
  14. Jakeh83

    Loose neutral wire

    I've recently had my house rewired all is working ok but when i plug in my socket tester on both ring mains there is a neutral fault, would this indicate a fault at the board or has a neutral popped out on a socket? How would i locate this neutral without removing sockets? Only thing that is...
  15. Jakeh83

    Nest E wiring

    Its currently wired through a programmer with the LR and LS link in, should i just remove the programmer and use the LR and LS connections? It needs a wire for the DHW though