Recent content by jamesmcbride

  1. J

    Which of this notifiable?

    you should register work within 30 days of completion
  2. J

    Extending TV coax cable from loft

    I tend to use a hole cutter as you get a nice bit to put back in after if necessary - say around 70mm
  3. J

    london rates

    I think you mean at least £50 ph
  4. J

    Extending TV coax cable from loft

    stick a (thin) nail through the ceiling where you want to bring the cable down the wall - easily filled after. Measure to the middle of the wall, 20mm hole down, cable rod through the eggbox stuff. Done it several times myself, makes for a very neat install, especially if you drop the power...
  5. J

    Conceal External Wiring for outdoor cctv

    As others have said, I'd drill through at 1st floor level, or, my preferred method, put the cameras on the soffits and run the cables in the loft space.
  6. J

    Lighting project I need a little help with please

    Actually, this and a dimmer would do it: https://www.rapidonline.com/finder-12-71-8-230-0000-16a-digital-weekly-time-switch-spdt-co-250vac-49-3007 Dimmer to Terminal 1 Lights to Terminal 2 Existing time switch to Terminal 3 L & N to the terminals at the bottom
  7. J

    Lighting project I need a little help with please

    I would suggest doing this with some "smart" technology. I would recommend the fibaro dimmers, but with these you really need a full blown home automation system to control them. If you're not thinking about expanding the automation of things, something like this...
  8. J

    Suggestions for a cable finder

    I find a tone generator and inductive amplifier very useful for cable tracing (mains or data) - although my background is more on the comms side of things. The handy thing is once you put a tone on the cable you can pretty much trace its exact route through ceilings, walls etc (assuming its not...
  9. J

    Non-compact LED lamp recommendations

    I'd say a "filament" style LED like this: https://www.internationalleds.co.uk/filament-led-bulbs/amber-tubular-3w-e27-es-led-filament-bulb/8067 would probably be the best bet? I've have a few of the more normal shape ones in table lamps etc that I got from amazon a few years ago and they seem...
  10. J

    Wiring 4 cables to a plug

    Or in reality fed from a 16a mcb. As flameport mentioned, the problem with the 13a plugs is the fuse
  11. J

    Wiring 4 cables to a plug

    Or as BAS says, a BS 546
  12. J

    Wiring 4 cables to a plug

    Sorry, I should have mentioned that you'll probably want to fit an outlet with an interlocking isolator, such as: https://www.tlc-direct.co.uk/Products/MKK9610BLU.html and note on the installation certificate the deviation
  13. J

    Wiring 4 cables to a plug

    As Simon has mentioned, if you still have the old plug, the best thing to do is going to be to use a continuity tester to determine which wire goes to which pin on the plug. If any? Regarding the issue that caused it, I would suggest if you are going to continue to charge using an extension...
  14. J

    Plug wiring colours

    Is it an iec (kettle) lead? It sounds like a chinese version
  15. J

    wiring a type 6013 relay switch to a float switch

    Is the "250v ~ AC MAX" *rating* not the contact rating, rather than the coil voltage? Could you get a clearer picture of the model number at the bottom I can't quite work out if it says 230v or 24v? Thanks