  1. J

    Wintex Connection Could not be Established

    You was bang on the money secureiam. I was on a texecom site but not the same as the one you linked to. Downloaded the latest version and she connected right up.
  2. J

    Wintex Connection Could not be Established

    Which website? Texecomm website shows Current software version: 8.1.0
  3. J

    Wintex Connection Could not be Established

    So im using 8.1. I got it from Texecomm.
  4. J

    Wintex Connection Could not be Established

    I think main issue is my internet is via a 4g modem and port forwarding isn't great. It works on USB but not via SmartComm
  5. J

    Wintex Connection Could not be Established

    Think I've solved it. I unplugged the COM1/2 and connected the Wintex cable to the Com2 and boom she connected. Really appreciate all you help.
  6. J

    Wintex Connection Could not be Established

    So I need to solder this on to my panel? Is there no way to use it without soldering it on? Or can I unplug the smart comm and use com2 then replug back in after I'm done?
  7. J

    Wintex Connection Could not be Established

    Thank you, attached is the two ports I tried. Top one with the PCB adaptor and switch on PROG and the other with the cable directly.
  8. J

    Wintex Connection Could not be Established

    You mean the one top middle where you put the red ribbon cable on the left with the 1. I did that also and got same error. I also get same error with SmartComm which works fine on the app?
  9. J

    Wintex Connection Could not be Established

    One was already set I suspect for my SmartComm module for setting and unsetting the alarm. I also try connect via that but it says the same error. I plug the cable into the engineering keypad plug on the left hand side of the board.
  10. J

    Wintex Connection Could not be Established

    Ah so I am not sure about that. Where do I set that in both panel and Wintex? I set the UDL password on wintex to same as panel if that's what you mean
  11. J

    Wintex Connection Could not be Established

    It says COM4 which is the usb port.
  12. J

    Wintex Connection Could not be Established

    Hello I am connecting with Wintex for the first time and not sure why it will not connect I created a new site and added the upt password in the site details. When I connect using PC-Com it just says reading panel type and serial number then after a few moments an error saying it can not...
  13. J

    Texecom Premier Elite 24 - Arming Issue

    Who said they have a bedroom...
  14. J

    Texecom Premier Elite 24 - Arming Issue

    Just so if one of the kids down at 7am before we are up at weekends it's automatically disarmed.
  15. J

    Texecom Premier Elite 24 - Arming Issue

    Is it possible to part set on a timer