it sounds like system still airlocked.first thing to try now is to shut off all your other rads and just leave the problem radiater on ,it then should push through and start circulating again,once hot ,open up your other rads
u should see a 'd' symbol when hw being used or is on preheat mode
and a 'c' symbol when ch on
if ur not seeing a 'c' then promblem with external controls not calling for heat,also check u have no dripping hw taps ,as if so this will leave boiler in hw mode
could be hot water temp sensor being silly causing the burner to modulate up and down as it doesn't no what temp its at
also could be flue problem
is the flue on your boiler standard through the wall type or does it go vertically upwards
not really a diy job as gas valve needs removing to access the brass so u can remove the guts of the valve ,if u carnt put up with the noise get a gas safe engineeer to sort for u.