  1. M

    Monobloc pushfit flexi pipe removal

    Am i right in thinking you mean the push fit connections into the base of the mixer tap and not the push fit pipe connections as shown in the photo.
  2. M

    rattling radiator

    Sounds like you have a faulty Thermostatic rad valve. Try removing the thermostatic head from the body of the valve. (Usually unscrews). This will keep the valve wide open. Run the heating as normal and see if the rattle stops. If so you need a new thermostatic valve. Hope this helps
  3. M

    electric supply to workshop

    As long as the cable is terminated properly to maintain the earth and it is buried deep enough out of harms way it should be fine. One thing i would say is that if you intend to install 5 double sockets and you are connecting quite a lot of electrical equipment i would think about installing a...
  4. M

    Veritas 8c manual

    Copy the following link into you address bar and it will direct you straight to the engineer manual. Go to page 20 and follow the instructions for lost engineer codes. Then re programme your own code. Good luck [url removed]