Recent content by mccanno

  1. M

    2 lights, one spur, only one light working

    you mean like this
  2. Untitled

    Untitled

  3. M

    2 lights, one spur, only one light working

    Catch 22. If it was a standard setup, I wouldn't have needed any help!
  4. M

    2 lights, one spur, only one light working

    @ ban all sheds - I thought that my diagrams were very explanatory in fact! I didn't for a minute think that you would be at all interested in my shoe cupboard and so, I didn't think that the detail or reasons for the setup were so important to you. perhaps if you'd taken the time to ask I...
  5. M

    2 lights, one spur, only one light working

    Yes. Its for a large cupboard. The first light is overhead, the second light is for a deep cupboard within that cupboard, where we store shoes. Entering into the cupboard needs a light on but not necessary at second level if no access to shoes is required. If the shoe cupboard light is kept...
  6. M

    2 lights, one spur, only one light working

    YES This is EXACTLY WHAT I AM TRYING TO DO, my friend. To have the second light only switch on if the first is switched on. Thanks for your answer, that's all I needed to know!
  7. M

    2 lights, one spur, only one light working

    Yep, I know. Im in now though, dived in and need to paddle!
  8. M

    2 lights, one spur, only one light working

    OK. That is how the system is set up. Assuming that all this is in place I have included a diagram of how I intend on wiring the switch, based on my getting a grip of what you are saying. I know that the blue wire is now switched live but for simplicity I have kept it blue in the drawing. But...
  9. Untitled

    Untitled

  10. M

    2 lights, one spur, only one light working

    are you referring to the most recent diagram in this post, or the first?
  11. M

    2 lights, one spur, only one light working

    Do you mean like this? but keep the live wire continuous at first light as in drawing 1?
  12. Untitled

    Untitled

  13. M

    2 lights, one spur, only one light working

    OK, so if I amend the setup as detailed in this drawing, everything should work? Amendment details. 1. Change the continuous live wire to connect to the first light. 2. Bridge the neutral at the switch, like it is done with the live wire. Thanks
  14. Untitled

    Untitled

  15. M

    2 lights, one spur, only one light working

    Yes, two lights. having problems at the switch with regard to bridging the neutral wire. I think the issue may lie in the live passing by the first light, see my diagram. The only wires connecting to the first light are the earth and neutral