Hi everyone need a bit of advice have fitted my new white kitchen and very proud of it and now I want to lay down floor tiles which I have done before but the problem I have is that I want to lay down black gloss polished tiles but have heard they are a nightmare cause they scratch so easily and...
Hi thanks for the suggestion my company has got all the relivent documentation licenses and liability to work in schools as its our profession our main area is audio visual such as projectors electric screens and sound systems, the reason I ask the question is that I haven't wired a lighting bar...
Hi everyone I have a question I am installing a lighting a lighting bar in a school to run about 6 lights onto a stage they are not your usual 15a lights they are going to be LED lights pulling a max of about 2000 watts I was wondering if I could spur off a ring main with a switched fuse box to...
thanks i think its all working fine now cause when only the hw is on the valve is off and when ch is on as well as the hw then the valve moves to the 1st position only and when the hw is switched off the valve moves to the 2nd position feeding the ch only and when the ch goes off the valve moves...
hi mandate so what i can gather when its in auto when the ch is off the valve is off the switches telling the hot water to fill the tank till its satisfied and when the ch is on the valve then turns till it makes both micro switches the direct the water to the rads
thanks
mel
Hi mandate thanks for the information it makes sense what the valve does now but as I said I took the casing off the new valve and its not moving anything inside I have to force the pressure switch with a screw driver for the central heating to come on
Thanks
Mel
Hi I think I have wired it correctly I matched it to the same as the old one and I can't move the lever cause I opened it up and it doesn't move anything
Thanks
Mel
Only me again update as i have left the screw driver on the micro switch the downstairs rads are hot now going to turn the upstairs on again to see what happens by the way if i have this micro switch pushed on does that mean its in auto or manual
thanks
mel
hello i tried to fire my heating up and nothing happened i turned the thermostat up on the boiler nothing and my house thermostat is on 30 and still nothing so i check my new valve and the man auto lever is just loose in either direction so i opened it up and the lever isn't doing anthing and...
Hi everyone first time on here and i would be greatful for any help as i just purchased a tower mid position valve, fitted it and fired everything back up at first i got all the rads on upstairs and downstairs and my hotwater is as it should but now only the upstairs are hot and down are cold so...