Recent content by nearlypastit

  1. N

    Baxi Solo 3 PFL 50

    Yes it looks like the one in the photo. Honeywell Sundial Y Plan 3 position Diverter Valve.
  2. N

    Baxi Solo 3 PFL 50

    Thanks for your advice. I think you are right, the motorised valve does seem to be the problem. My problem now is to change it. The valve is situated right at the back of a low cupboard so I am working myself up to crawling in on hands and knees and working in cramped conditions. The...
  3. N

    Baxi Solo 3 PFL 50

    Thanks for that, I am just off to the hospital yet again to visit our friend. I will try this when I get back. I had noticed the little lever on the top of the valve and I can see where it should clip in.
  4. N

    Baxi Solo 3 PFL 50

    Sorry for the delay, I have had a busy weekend (I'm getting too old for all this DIY lark). The pipework running from the pump goes to a 3 position diverter valve. The pipe leading to the valve and the two branching off are all hot when the boiler is on but I am still not getting the rads...
  5. N

    Baxi Solo 3 PFL 50

    The pump is in a cupboard under the stairs and attached to the pipework nearby is what looks like a valve. I could feel some heat on the case and also the pump felt like it was running. I have got to stop at this point as I am off to the hospital to see a friend who has had an operation this...
  6. N

    Baxi Solo 3 PFL 50

    Not sure where to start. I'm not a heating engineer, I am a retired domestic appliance engineer, on a pension so trying to save money by repairing it myself. The boiler seems to have the main gas valve with a solenoid beside it, a potentiometer, a thermistor, a overheat stat and a pcb (which I...
  7. N

    Baxi Solo 3 PFL 50

    I have a Baxi Solo. The hot water side is ok but I cannot get the C/H side to work. I thought at first that it was the room stat as it was quite old. I fitted a new stat and also fitted a new programmer at the same time as it needed an upgrade. I still have the same fault, hot water fine, no...
  8. N

    Baxi Solo 3 PFL 50

    I have a Baxi Solo. The hot water side is ok but I cannot get the C/H side to work. I thought at first that it was the room stat as it was quite old. I fitted a new stat and also fitted a new programmer at the same time as it needed an upgrade. I still have the same fault, hot water fine, no...
  9. N

    Ford Focus passenger door panel

    You've got me nervous now, think I might get someone to fit it for me, I'm getting too old to have all that hassle.
  10. N

    Ford Focus passenger door panel

    I'm still not sure what happens to the inside door handle, it must be attached to the outside handle. Is it attached by a cable or do I need to remove anything else?
  11. N

    Ford Focus passenger door panel

    Thanks, what happens about the door catch (inside)? I have removed the screws around the edge and the one above the handle but the panel doesn't seem to want to come off
  12. N

    Ford Focus passenger door panel

    I need to remove the inner door panel so I can replace the electric mirror. I can see the the screws around the edge and the one behind the door handle. What else do I need to remove to gain access to inside the door. I have the new mirror and it looks like it is held on by just one bolt. Any...
  13. N

    Bosch WFL 2450 leaking

    I haven't worked on appliances for a few years but normally, after undoing the 2 screws at the rear, the worktop should push back. It will be fastened with keyhole shaped fittings at the front. If this is incorrected then sorry. I did work for Bosch for 20 years but appliances may have changed.
  14. N

    Baxi Solo 3 PFL 50

    Ordered new pcb yesterday, arrived this morning at 0945. Fitted it by 1030. All working correctly. Thanks for all your advice. nearlypastit