  1. N

    8.5Kw Shower questions

    no, it's the influence of a Degree in industrial automation and all the health & safety therein; if there's a possibility of a safety device not operating properly every time, use more than one since the probability of both developing the same fault goes from "highly unlikely" to "freak occurrence".
  2. N

    8.5Kw Shower questions

    this was my thought on the matter, purists might call it excessive, I'm calling it built-in redundancy
  3. N

    8.5Kw Shower questions

    I know right, there was me thinking they were to detect an imbalance...
  4. N

    8.5Kw Shower questions

    I should stress that the circuit for the shower was already in place but for reasons best known to the council - who renovated the electrics a few years back while I was renting - they'd used ~1.5-2.5mm wire and spliced it into one of the plug sockets. (yes, really.) and as such you'll...
  5. N

    8.5Kw Shower questions

    sorry, should have explained; I bought this http://www.diy.com/departments/wylex-63a-sp-30ma-shower-protection-unit-rcd/177830_BQ.prd which it turns out is CU type RCD in a plastic box with a rail at the back. ~ hence the question of skipping the necessity of messy wiring between a switch the...
  6. N

    8.5Kw Shower questions

    hi there, I'm new to these forums (although I've read more than a few posts while planning my modest project) here's what I know; the shower needs a local isolating switch - this is provided by a 45A cord-pull switch. the shower requires a dedicated 30mA RCD - got the shower requires 6mmSq...