Hi again
Just to advise that the new pump has fixed my boiler. No leak and no problems with first start up in the morning. Probably could have go away with a new solenoid valve but did not want to chance it when the weather is so cold.
:D :D :D :D :D
Thanks
Leak is definitely from the nozzle - the exterior of the pump and connections are dry. Guess gravity is pushing it through as tank oil level is higher.
I will clean the baffles, have also ordered some glass rope as the baffle door gasket is perished. I think this would be better...
Thanks Burnerman
Yes - I did have a thump or two on startup - if you mean the excess fuel detonating?
I would think that the pump is delivering pressure ok, but suspect the solenoid valve is allowing fuel through by gravity when the boiler is off, which would explain the puddle and the fan...
Hi All
Just wondered whether anyone has expereinced this problem?
Our Trianco Eurostar outside boiler started to lock out on its first morning start, although not every morning. Once the santronic lock out was reset it fired up and ran fine all day. To get by I added an early morning...