I believe the fire resistant tanks are good if you get the local building inspector to sign it off. Oftec technicians can not sign them off as the tanks do not have oftec fire resistant approval. It may be the case that not all labc's approve of these tanks either so it's a good idea to ask them...
Hi folks. A family member is renovating an old cottage and has asked me to install an Ecodan air source heat pump. All the insulation is top spec and the company supplying the pump and under floor heating is happy that it will work well. They sent me on a course (i'm usually oil) and feel ok to...
AFIK there isn't a modulating oil boiler available.
I agree with Delta T2 about pipework arrangements but would usually fit Grant boilers given the choice, although Firebirds heat only offerings seem ok. Stix.
Undoing the 4 allen bolts to reveal the filter is ok. If you've undone the 3 allen bolts under the filter where the 1 pipe washer is the pump will be scrap because they cannot be rebuilt by hand properly. Needs factory machine assembly. Get someone to fit a new pump and set it up properly. Stix.
When the new pump was fitted check with your guy that the bypass screw was screwed in. This is a small grub screw like thing which needs fitting in the return port of the pump when using a tiger loop. I did go to one once which was supposed to have had this done but on inspection the screw was...
I need an oversink water heater either instantaneous or up to 15 litres which can be drained in freezing weather as its in an unheated workshop.
Can anyone recommend one or an easy method for regularly draining standard heaters in cold weather please ? Our instant one blew apart last winter...
temp control must work to some extent or it would trip overheat stat. could the flowswitch be stuck ? did have one once but on different boiler with same symptoms.
If it's not been serviced in a while the exp. vessel will need recharging. To do this release all the water pressure till the gauge reads zreo. Then using a car tyre pump, pump the vessel back up to 1 bar. Charge the water up to 1 bar again .Stix.