Recent content by pototea

  1. P

    What's the name of this dado rail and skirting?

    I need a section of dado rail.and skirting replaced in my house. Does anyone know the profile name of the dado rail and skirting and where I can buy a short length of 1m each? It's a Victorian house. Dado rail is 3.5cm and skirting 17.5cm. Surely they must be common but I can't find for the...
  2. P

    New Roof Needed - What Should I Be Looking For?

    Thanks and yes I agree they are not all the same and I don't know which one looks right! My comment about Spanish slate vs Welsh slate yes I know Welsh is more expensive but I am being quoted £10k as an "upgrade fee" which doesn't sound right for an area of 3x x 6m. This means I am paying ~£15k...
  3. P

    New Roof Needed - What Should I Be Looking For?

    I am a home owner and have a mid terraced Victorian house in London. The back roof needs replacing (over 100 years old, minor leaks). I've got four quotes but since I'm not an expert I don't know what I should be asking these guys, what material they should use etc. Can anyone help? Some...
  4. P

    Siemens Washing Machine - Knocking Noise On Medium Spin Speed

    Ok so I have moved the drum as much as I can. From side to side there is very little movement and it doesn't hit anything. There is no noise when I rotate the drum by hand. When I move it back and forth - if I push it hard enough then it knocks the back panel of the machine. However I have...
  5. P

    Siemens Washing Machine - Knocking Noise On Medium Spin Speed

    Thank you (both) :) I will check tonight when I get home.
  6. P

    Siemens Washing Machine - Knocking Noise On Medium Spin Speed

    I have a ~10 year old Siemens washing machine. On medium spin speeds there is a knocking noise. The volume of the noise / shaking of the drum varies depending on the load weight. When I wash bed sheets and towels the noise is louder and the drum moves more than a clothes load. I typically fill...
  7. P

    Recommendation of single zone underfloor heating manifold?

    Hi there, I nees to replace my single zone underfloor heating manifold + pump in my 30sqm kitchen (long story why). Does anyone have any recommendations of a brand of manifold and where to buy from? Many thanks,
  8. P

    Ufh not heating properly - boiler goes on / off every minute

    Hi, I've already had three "experts" look at it and no root cause identified by any of them yet. Unfortunately i don't have a system diagram. It's a single room loop and I have two zones - one for radiators and one for the kitchen ufh. It initially worked for 2 years after first installed...
  9. P

    Ufh not heating properly - boiler goes on / off every minute

    Thanks. Is anyone able to identify from the photos what the brand of manifold Is? There are no markings whatsoever on it. Potentially it may have been bought from Screwfix or Toolstation in January 2016. These companies only sell John Guest manifolds. Can anyone confirm this looks like a John...
  10. P

    Ufh not heating properly - boiler goes on / off every minute

    Hi there, I had a third plumber come today. He believes the problem lies with the pump sensor (box in photo). There is no branding on the sensor so he is unable to replace it with another one. He has suggested removing it all together and advised that its am extra precautionary measure and not...
  11. P

    Ufh not heating properly - boiler goes on / off every minute

    Update - I had a plumber come today who spent around 1.5 hours looking at it. He couldn' figure out what was wrong so he called grundfos. Grundfos said the pump is not right for underfloor heating, it' too powerful which is why the heating keeps switching off as most likely it's over heating...
  12. P

    Ufh not heating properly - boiler goes on / off every minute

    Yes there is a green light and it gets hot. The plumber changed the pump twice so we've ruled out a pump issue.
  13. P

    Ufh not heating properly - boiler goes on / off every minute

    Hi there, Photos attached. The arrow is pointing down into the floor.
  14. P

    Ufh not heating properly - boiler goes on / off every minute

    Hi there, yes it's certainly a possibility it's the wrong way round. When the plumber fitted the first pump that broke down he originally fitted it the wrong way round. It was only when I called another plumber who identified and corrected the issue that the heating started working again until...
  15. P

    Ufh not heating properly - boiler goes on / off every minute

    Hi, the floor is getting no where near that temperature. It barely gets warm and it's patchy. It was working 2 months ago before the pump broke down. Here are some more photos
Back