Recent content by progcwj

  1. P

    water boiling & spluttering into f/e tank

    BG engineer replaced boiler stat, c/h system now working fine. :)
  2. P

    water boiling & spluttering into f/e tank

    I called British Gas last Wednesday, explained about the problem, i.e. faulty boiler thermostat, and a visit was arranged for the following Monday. Engineer duly arrived, tested the boiler, said that the stat was indeed faulty, and ordered a replacement, explaining that he could not bring the...
  3. P

    water boiling & spluttering into f/e tank

    I tested voltage between boiler stat & gas valve, after turning stat to "0", and it was still live, which indicates a faulty thermostat. Maybe room stat was a red herring - time will tell. Decided on service contract with BG, probably cheaper in the long run. The boiler was installed Dec 87...
  4. P

    water boiling & spluttering into f/e tank

    To ChrisR: GC number of Hideaway 50 is 41 313 15. To bathjobby: F/e tank is half-full, water level 3 to 4 inches above feed, well below overflow. I will further test boiler stat later as per fault finding chart which appears to be pretty comprehensive. Thanks for your reply. :?
  5. P

    water boiling & spluttering into f/e tank

    To Whiter: Boiler thermostat does not turn boiler off when it is getting hot. The radiators are getting hot before it starts spluttering. If I turn the boiler stat to Min or even to "0" does not turn it off, but turning the room thermostat down until it "clicks" does turn the boiler off...
  6. P

    water boiling & spluttering into f/e tank

    To ChrisR: Boiler is glow worm hideaway 50, stat knob is white hat shape. Have turned down boiler stat to halfway between max & min. To Whiter: Pump is working. For what its worth I have bled pump & all radiators, only one emitted air, all working ok. Last night I cleaned dust from room...
  7. P

    water boiling & spluttering into f/e tank

    Soon after c/h comes on automatically in morning, water circulating from boiler reaches boiling point, creating steam in the airing cupboard, and water in the f/e tank is piping hot. Shouldn\\\'t the boiler automatically cut out? If I manually turn down the centrally positioned room...