    Knock through, RSJ and end bearers

    Thank you, that is something interesting. Does that mean when I chase the joining wall for new electrical sockets and cable runs that I need a PWA? Also does that mean the new extension I have built along the boundary is a shared wall?
  2. P

    Knock through, RSJ and end bearers

    Would it be possible to sit the steal on the joining wall between me and my neighbour but solely on my brick/block work?
  3. P

    Knock through, RSJ and end bearers

    Thank you that makes sense. My builder prefers to install two steels but the second option also seems viable. I will be speaking with the SE tomorrow to discuss my options regarding steels and piers.
  4. P

    Knock through, RSJ and end bearers

    Thank you. Yes from reading posts on here even I am cofused as to why the bco has not insisted on calcs. BCO is part of a reputable company. Regardless I want calcs as safety is the most important thing for me. Tony, from your experience would I have two steels (for cavity wall) bolted...
  5. P

    Knock through, RSJ and end bearers

    Hi Tony Thank you for your thoughts. That puts my mind at ease as initially I was happy to leave 300mm piers. Should I approach another SE? If so can you reccomend anyone? He was charging me around 175 + vat. I don't know if that is good or not. Thank you
  6. P

    Knock through, RSJ and end bearers

    Hi, I have a 3 bedroom end terrace (ground floor and first floor with truss roof), i have had an extension built to the rear of the house via permitted development (external size 3mx7m with vaulted roof). I now want to knock through the back of the house which is a cavity wall (260mm). The...
  7. P

    Knock through, RSJ, End bearing and SE

    Payment is not the issue. I rather not waste his time and effort if he believes I need such a large end bearing. I will then have to explore other avenues to use the space. Thanks I will post in the building section.
  8. P

    Knock through, RSJ, End bearing and SE

    Yes, which I thought was normal. I do not want to pay the money and the have the SE say that I need 600mm end bearers. I am no expert at all but 600mm seems incredibly large.
  9. P

    Knock through, RSJ, End bearing and SE

    Sorry for the double post. I am happy to change SE if anyone believes that may help, i am in the Leicestershire. thank you
  10. P

    Knock through, RSJ, End bearing and SE

    Hi, This is my first post, for a while I have enjoyed reading through many posts and learning :). I have a 3 bedroom end terrace (ground floor and first floor with truss roof), i have had an extension built to the rear of the house via permitted development (external size 3mx7m with vaulted...