    Connecting to an adjacent felt roof

    Hi all, I intend to connect to an adjacent flat roof using EPDM, using all recommended materials IE. Termination bars ect. Where exactly is best to cut back to? The roof felt to be taken off is on the left hand side in the pictures. Thanks, Richard
  2. R

    EDPM rubber roofing

    A bit yes as I own 2 flat roof propertys which ive had since 2005, Why? I don't see how this is reliant to the price.
  3. R

    EDPM rubber roofing

    Yes I am they took my details
  4. R

    EDPM rubber roofing

    Hi All, Ive been on and passed the Permaroof seminar/training course so, i am approved. Ive just got a quote through my training company today and find the water based bonding adhesive very pricy £66 for 10 litres and the membrane itself - 6.7 x 5.6 £260. Is there anywhere that can provide a...
  5. R

    Central heating problem (Open vented)

    Sorry i don't have any info i do think it could be an air lock
  6. R

    Central heating problem (Open vented)

    Hi its the cast iron stand alone radiator but I cant see why that would make a difference, I have tried turning off the other rads to push the heat through as like you would when balancing radiators but no luck :-( yes maybe an air lock thinking about it..
  7. R

    Central heating problem (Open vented)

    Hi all, Ive extended some central heating pipes into a conservatory. I capped off the new pipes filled up bled all radiators in the house everything fine. The new radiator arrived today, I noticed when I took one cap end off a pipe I assume the return they was no water just a slight suck of air...
  8. R

    Three Phase question

    Hi John, Unfortunately there is no chance of my property having gas, I dont think the DEX has a quick enough heater to cope with a bath
  9. R

    Three Phase question

    Do you have a link for an electric combi? it would be nice to have CEN :-)
  10. R

    Three Phase question

    Hi no i have a standard home consumer unit i was hoping they would be a way round it ie. maybe a separate RCD box and breaker, and no other unit if you look at the spec sheet can fill a bath. I want to take out my cylinder and header tank and replace with the DBX18.
  11. R

    Three Phase question

    Please take a look at the literature for Zip hot water heaters by the link below. (opens as a PDF) I would like to get a DBX18, My question is by the looks of it I can not install it as like you would say a 7kw shower as its a three phase unit. what would i need to do exactly? Thanks, Richard...
  12. R

    Vented combination cylinders

    Hi they is limited space where customer wants it installing and yes will look into Nottingham company, in the mean while is 900mm the smallest standard size?
  13. R

    Vented combination cylinders

    Hi im looking for as small as possible combi cylinder, It will need ho have an immersion heater as there is no central heating to deal with. It will be feeding HW to a bath, wash hand basin and kitchen sink. any help would be much appreciated thanks, Richard
  14. R

    Extractor fan advice please

    Sorry i ment pull swich
  15. R

    Extractor fan advice please

    I have a feeling L2 comes into play,I have wired up my fan as in Dig 1. But would like to wire it up to Dig 4, which cable from the rose L1 or common? Or do I use L2 and put it in terminal 2...