    Minor works cert

    cheers for your replies i appreciate the comments. the other day at work, in someones house, i disconnected a shower that was fed off the downstairs lights. the guy removed a smoke detector cut the three core 1.5 cable JB'd it and then ran a 6mm to a pull switch and then to the shower...
  2. S

    Minor works cert

    In that case I would consider doing an EIC, little more time but a**e covered! for 6 inches of cable?
  3. S

    Minor works cert

    actually i wish io'd just said i was too busy
  4. S

    Minor works cert

    i replaced a 2.5/1.5mm Twin and earth red and black with a piece of 6/2.5mm twin and earth, when i removed the sockets to check them, one is fed with a 10mm cable and the previous installer jammed a 2.5 in there too. the cables were loose in the back of the socket. so where there were...
  5. S

    Minor works cert

    to repair the cooker circuit i replaced 1 socket with a cooker outlet plate and went from this to an existing socket in blue and brown 6mm/2.5mm cable of a length approximatly no more than 6 inches to a socket outlet that was already there.
  6. S

    Minor works cert

    Job was 1 Replace fan in bathroom. Replace existing fan that sounds like chain saw with new fan. 2 Repair Cooker socket. Cooker fed in 10mm to cooker switch from cooker switch in 10mm again to 2 single sockets in cavity under hob and behind cooker. one socket fed in 2.5mm and...
  7. S

    Blu cube speakers and QED stuff

    SS40 Wasnt right problem was solved by replacing SS40 with SS50
  8. S

    Blu cube speakers and QED stuff

    i've taken the volume controls out of the wall and connector blocked all the cables together L + R pos and negs. i turn the ss40 on and activate all speakers. all speakers come on. soon as the volume controls are re added the fault comes back. also i added a Btech BT 13 4 way switch and...
  9. S

    Blu cube speakers and QED stuff

    wired a speaker system in a flat. contains 4 sets of speakers, one 4 way switch and a CD player. the speakers are blu cube, the QED products are the wall recessed volume controls, 4 in total the 4 Way switch The CD player is ONKYO. wired all volume controls fine and wired...
  10. S

    Offsite deactivation of burglar alarms

    alright, ive been recently asked about burglar alarms and whether they can be remotely deactivated in case of false alarm. the owners of said flat live over an hour and a half away and would like this option. i am not a burglar alarm installer and have told them this. but curiousity killed...
  11. S

    leccy board seals

    I heard that you can go on a day course in changing meter tails, but apparently this allows you to be able to legally replace seals. APPARENTLY! now i dont know if this is true or not and would like it if you all may be able to help me with this query?[/b]
  12. S

    Points served Question

    1 light fitting has 3 GU10 lamps in it. my question is is it 1 point served or 3 Due to the number of bulbs
  13. S

    just some photo's for ya's

    i thought i would submit some pictures, some where im possibly reqiring in the future luckily not alot of time will be spent in here. asbestos flash pad in mem switch, tasty
  14. S

    Hager Mini Gamma

    http://www.tlc-direct.co.uk/Main_Index/Consumer_Units_Index/Hager_Enclosures_Range/index.html
  15. S

    Hager sollysta gear

    are the hager sollysta range reasonably priced compared to mk havent had chance to ring the wholesalers yet and i've heard they are alright to fit just wondered what other people thought