I know its been a while but just wanted to put on here what the conclusion was in case it helps someone else.
We got british gas back out and a different engineer turned up, he confirmed that it was not right and that he thought it was a problem with the secondary heat exchanger. He then...
Thanks for your advice it is very much appreciated. so just to confirm even with kitchen hot tap for example on full burner should stay lit.
i understand that i will lose temperature the faster the water is flowing, but want to confirm the main point is burner should stay lit and not keep...
assuming temperature sensors ok as when i turn dhw dial nown i see flames reduce. and also when i adjust central heating dial down when central heating on the boiler cuts out and comes back on when dial turned up.
thanks again steve
british gas came back today and fixed flue. he said that hot water going hot and cold when tap on fast is normal for a combi boiler, as the heat cannot pass from primary circuit to water for dhw aswell when flow rate high, so primary circuit temperature max's out causing boiler to shut down for...
Just an update:
had british gas out today as burner stopped kicking at all last night on both hot water and central heating no matter what i did. they replaced pressure switch which got it working and he checked taps all ok. when i got home from work tried hot tap on full and original problem...
Hi i eventually got secondary heat exchanger out today to have a look before i purchased a new one and found it very clean, on flushing it out.. the reason i got round to it today is that the boiler is still doing above fault, but has also developed a new one. What it also does now is that when...
Hi
I have a ariston microgenus 23 combination boiler, the problem i have is with the hot water only, central heating seems fine. When i run any of the hot taps fully open the boiler delivers hot water for about 30 to 40 secs, the the burner cuts out for about 10secs causing the water to go...