Recent content by tspark3009

  1. T

    New motor noise

    Guess I will have to try a new pump
  2. T

    Riello 40 burner - Resistance in motor shaft

    The position of the fan on the shaft has to be correct so it doesn't catch the casing
  3. T

    New motor noise

    Oil pump is only a year old unlikely to be knackered, I understand it's rare for the oil pumps to go noisy
  4. T

    New motor noise

    Fitted a new blower motor to my Heatslave 20/25 as the bearings were shot, although the bearing noise is cured this motor is not as quiet as the original used to be, EOGB motor are they quality motors? Thanks
  5. T

    Stripping emulsion off plaster

    I have a poor multi layer emulsion on plaster job to remove, it's flaking away can get my scraper behind it in places. It's been put on layer after layer and no misting coat was applied. Reluctant to use my steam stripper as the heat blows the plaster skim off in places. Is there a good chemical...
  6. T

    Cooker hood ducting

    Hello Just in the process of installing duct from an internal wall across the ceiling void to outside wall for a hob extractor hood. Method as follows I'm going with flexible from an under unit extractor through the cupboard then to manrose 204x60 rectangular duct up the wall to a right angle...
  7. T

    Fitting wall mounted waterfall bath filler

    Wall mounted waterfall bath filler that is going to sit flush to my tiles, it is a solid unit with a male 1/2" G thread connection, do I leave a wall plate elbow recessed in the tiles and thread the whole thing into it using ptfe. If you have a look at Hudson and Reed code PN300 that's the one
  8. T

    Danfoss 071N0010 cheapest

    Danfoss 071N0010 where is cheapest place to purchase online?
  9. T

    Heatslave 20/25 lockout oilfired

    Worcester Heatslave 20/25 lockout What is my fault tree, oil supply is fine, whats next photocell? How do I check the oil solenoid and the oil pump are working
  10. T

    Securit 800l

    Turns out he entered the building through the wrong door and triggered an instant full alarm and didn't realise he needed to clear and reset, which means inputing the code & the # key
  11. T

    securit 700l engineers reset

    New house I have been given the user code but not the engineers code as the alarm was on contract and the company will not release the code to me but will come out and change it at a cost, yeah right. So as a qualified electrician I',m armed with my jumper link to do a power down reset to...
  12. T

    Securit 800l

    wasnt sure if it would go to constant tone as you closed the door on exit, but my guess is to initiate the set all zones need to be closed, then whilst the constant tone is sounding you can open the entry exit or activate any number of pir and it will not arm until the circuit is closed and held...
  13. T

    Securit 800l

    Securit 800l intruder alarm issue Set my alarm this morning, no issues, just got a call from father in law, called at the house (bear in mind its his first attempt at this) input the code within the entry time. When leaving the house he rang me to say he has an intermittent tone that will...
  14. T

    Securit 800l

    Securit 800l intruder alarm issue Set my alarm this morning, no issues, just got a call from father in law, called at the house (bear in mind its his first attempt at this) input the code within the entry time. When leaving the house he rang me to say he has an intermittent tone that will...
  15. T

    Lighting choice bedroom bridging units

    Looking for some dimmable downlighters (led) for the underside of my bedroom bridging units any ideas ?