Recent content by Xander2577

  1. X

    Riello bf3 issues

    Yes my oil tank is indoors and stays around 60 degrees F. It is cold here but the problem has persisted in the warmer weather as well. I'm going to start from scratch with the Riello tech specs and a different nozzle,also ordered the solenoid as suggested. You guys are great, thanks for all the...
  2. X

    Riello bf3 issues

    I'm burning number 2 oil. I called the RIELLO Tech support hotline as well. They gave me some new specs that apparently help with a low-sulfur fuel issue on this unit. .50 70 degree A nozzle, 160 pump pressure, air 4.5 and zero turbulator. I'm not convinced this small change will fix the problem...
  3. X

    Riello bf3 issues

    Working on an oil fired riello bf3. The unit is making two ignition attempts when cold. Starts every time on the second attempt. Does not lockout. Replaced filters, nozzle, photocell. What is the next likely culprit? Transformer? Fuel line vacuum is good.