Recent content by zimmers

  1. Z

    Air in central heating system

    Is there a bypass fitted,so your excess heat can circulate when the rads have reached temp,if not then the excess heat will have nowere to go and cause banging and push it up the expansion
  2. Z

    solid floor need channelling

    Is there any type of channelling kit,i can buy,i have a job starting and i have to run c/heating pipes in the floor,and as its solid,i need to channel and fit ducting,any ideas please
  3. Z

    Heating job.

    I fitted a combi in a loft last month and if its done correctly its great.As you say board it out,lighting and ladder,i fitted a timer and wireless roomstat and with built in frost stats and lagging its ok.I might put mine in the loft and gain a extra space in kitchen.With elec/ignitions it...
  4. Z

    Air in central heating system

    Was the b/room rad off the old h/water circs,now its fully pumped maybe you need a by pass or leave one rad fully open,if its getting air then is it pumping over into the h/tank. ,you would know if its still off the circs,so does it heat up on h/water only.If it does it is on the h/water circuit...
  5. Z

    Worcester 28CDi Hot Water works, but Central Heating doesn't

    I would be dubious about buying off the net,if i was working for a customer but i have bought 2 parts for worcesters from ebay,both sound,i got a pcb for a standard 24 i combi and it came as id get it from local supplier.I went to a job were he had bought a fan off ebay,for a ferroli,£135 and it...
  6. Z

    Worcester 28CDi Hot Water works, but Central Heating doesn't

    i know it works on h/water but take tube off aps and gently blow or suck and see
  7. Z

    Worcester 28CDi Hot Water works, but Central Heating doesn't

    So weve got fan,pump,have you tried just blowing down aps tube when its trying to ignite
  8. Z

    Gas Pipe in Floor

    No,just clip and identidty labels,so who ever comes across it,will know its gas.I clip mine with nail ins every 2nd joist
  9. Z

    Very noisy boiler after new pump fitted

    Why not,get a auto air vent fitted,on the circs and also drain down add a light cleanser,leave for 2 weeks,drain down and add inhibator.and see it helps,didnt servowarm used to leave there header tanks without mains to fill up,surely it fills properly now?
  10. Z

    Can you solder direct onto a brass draincock?

    Yes,if there the normal type,with the tail,that fits into 15mm fittings.take the inside out before soldering or washer will melt and leak
  11. Z

    Changing radiator valves without draining down

    Go and get pack of regin rubber bung kit,it is ideal for working on a conventinal system,put onbe over the expansion pipe and one in the header tank,plugging the cold feed,then find trvs that will fit the same nut ,so you can just fit the body,put some ptfe around them and i always run a thin...
  12. Z

    worester 24i boiler

    he only has to press the reset and he will know it doesnt have a pilot
  13. Z

    worester 24i boiler

    go to the top of the boiler,red button with a cross on press it down