Search results

  1. M

    Ideal Isar m30100 cuts out error LF when hot tap turned off

    Hello again, Yes, it has been fixed. The problem stemmed from the woven glass insulator around the inside edge of the cast aluminium combustion chamber. The insulation had moved and the flames were licking directly on to the aluminium, it could be clearly seen as discoloured in the front left...
  2. M

    Ideal Isar m30100 cuts out error LF when hot tap turned OFF

    Ideal Isar m30100 cuts out error LF when hot tap turned off The Ideal Isar m30100 which cuts out with error code LF whenever a hot tap is turned OFF. A week ago the flame detection electrode was replaced but the problem remains. The central heating is functioning ok, and when the DHW is...
  3. M

    Ideal Isar m30100 cuts out error LF when hot tap turned off

    Hi Martin, Thank you for the information. To answer your question, no, it is not noisy, it does not bang when the gas lights, and no rattles or grinding come from fan or pump, they all seem ok. To me the significant factor is that it is only when the hot water tap is turned off that the cut out...
  4. M

    Ideal Isar m30100 cuts out error LF when hot tap turned off

    Hello, I have an Ideal Isar m30100 which cuts out with error code LF whenever a hot tap is turned off. A week ago a boiler engineer replaced the flame detection electrode but the problem remains. The central heating is functioning ok, and when the DHW is running plenty of hot water flows...
  5. M

    How do you test the resistance on a pump ?

    I have just received a note from Caradon with resistance values for an Ideal Isar 30100 boiler: Fan: 110-130 Ohms Pump: 220 Ohms Diverter: 200 Ohms Gas valve: 4.2 K Ohms Hope that helps
  6. M

    Ideal Isar 30100 fan, how to test, coil resistance, 5 wires

    Hey you guys, thanks....it works again. I checked the fan resistance between red/blue and it was about 120 Ohms and so reconnected everything with fingers crossed and, Bingo! Incidentally, I had a reply from Caradon also who confirmed the fan resistance of about 130 Ohms About the jumpers...
  7. M

    Ideal Isar 30100 fan, how to test, coil resistance, 5 wires

    Thanks to both of you for your help, I will check this out now, being careful to watch the safety aspect....thanks for the warning!
  8. M

    Ideal Isar 30100 fan, how to test, coil resistance, 5 wires

    Please can anyone help me with information to test the fan on this boiler? The display went out and the boiler died. I have replaced the pcb with a refurbished one from http://myworld.ebay.co.uk/compumerv, excellent value at £55, and it was this engineer who said that the fan was probably the...
Back
Top