Search results

  1. W

    Weather compensation & Wireless TRV control

    Hi Lee, any idea if this functionality is in the Intergas HRE system boiler? If not, what are my options?
  2. W

    Weather compensation & Wireless TRV control

    ... but assuming I'm happy to have the WC disabled while the HW is being heated I'm OK?
  3. W

    Weather compensation & Wireless TRV control

    I didn't but I know the theory now: http://www.atmos.co.uk/wp-content/uploads/2012/02/TDS003-Weather-compensation-and-stored-hot-water.pdf. That's quite a n old doc. I'll find out if this is still applicable to the newer Intergas boilers. Imagine it is.
  4. W

    Weather compensation & Wireless TRV control

    Ok, after much research I have decided to not got for EvoHome yet since it will cost £1500 to kit out the whole house. It's tough as I love a gadget and I'm really really into the smart system idea but I think prices must come down significantly in the next 18 months as competition increases...
  5. W

    Weather compensation & Wireless TRV control

    Ah ok, so do you mean the Evohome overrides any data from the WC sensor (but is able to regulate the flow temperature because the boiler supports OpenTherm)? If so, does that mean there's no point in getting the WC sensor for the Intergas?
  6. W

    Weather compensation & Wireless TRV control

    Thanks Dan. I really want this to work (excited by both) but I'm concerned that the weather compensation and evoHome will conflict with each other. I'm not confident that they have been designed to work together. Can you go further to explain how they work together?
  7. W

    Weather compensation & Wireless TRV control

    House is square in foot print, detached, double fronted, about 2700 sq/ft with attic conversion. We have a 300L unvented cylinder (just fitted) currently supplying hot water off the immersion until the new boiler is fitted. No, not at all sure I need a 37kW boiler. It was recommended by our...
  8. W

    Open-plan: mix UFH and radiators

    Have just moved into a 30's detached, and starting from ground up with CH as old boiler and cylinder are broken beyond repair. The foot print of the building is square. With 4 rooms to make the square with staircase in the middle. i.e. double fronted. We are doing some minor building works...
  9. W

    Weather compensation & Wireless TRV control

    I've just moved in to new house and am designing from ground up as old boiler and cylinder are broken beyond repair. I spoke to Vaillant about using Evo in combination with their weather compensation and they told me it's one or the other but not both. I also spoke to Honeywell and the...
  10. W

    Unvented meltdown

    Thank you all for your answers. This makes sense. We have been turning the immersion on an off a couple of times a week so that may have accelerated the problem. I've got some confidence around the issue and we might be able to fix it in the short term before replacing in a couple of months...
  11. W

    Unvented meltdown

    Corroded terminal by wads posted 17 Jul 2015 at 11:59 PM Hi. I moved into a new house in feb 15. The boiler was broken so we decommissioned it and the heating. We reverted to using the immersion heater of the Ariston 500 STI Unvented system for hot water only. We ran out of hot water today...
  12. Corroded terminal

    Corroded terminal

  13. Stuff

    Stuff

  14. W

    render curved external wall - how to achieve 90degree edge?

    Hi, I've got a small curved garden wall that forms the boundary to a raised flower bed. The wall has been built with landscaping bricks with random relief. I want the wall to be smooth so I am in the process of rendering it. My question is how do I achieve a true 90 degree arris/edge of...