  1. L

    new room stat to be fitted ... 2 wire/3 wire

    Hi there again Right am off this afternoon and am going to replace it now finally!... the new stat also has a third terminal SAT but i just leave/ignore this terminal i believe ... (correct me if a am wrong please)! so the common terminal goes to 2 on my new stat (1 on the old one) and...
  2. L

    new room stat to be fitted ... 2 wire/3 wire

    thanks everyone for your views/info. ok my stat is a sunvic TLX 4101 it has a small info leaflet with it and it gives details on other room stats for when wiring the sunvic i have has common (2) dem. (1) and sat. (3) my old ACL TS142, according to the leaflet has; common (1) dem...
  3. L

    new room stat to be fitted ... 2 wire/3 wire

    Hi all I have bought a new room stat today to replace my old tatty one a normal room stat (not a prog or wireless type!) my old room stat is acl and i have bought a sunvic i know my old room stat had 3 wires and the sunvic one i have has 3 terminals 2: 1, 2 & 3 (although on...
  4. L

    Digital room thermostats...

    hi thanks all for your responses i am slightly confused now! ... my room stat currently has 3 terminals, i believe them to be common, call and satisfied. if the new room stat has 3 terminals these obviously just need swapping over (will the new room stat have instructions for this to...
  5. L

    Digital room thermostats...

    Hi I am thinking about changing my room stat to a new modern look programmable digi room stat! is the wiring the same.. ie. 3 wires, common, call and sat? i have looked at a few sites, drayton, etc to look at what's available. any recommendations from personal preference? also...
  6. L

    motorised vale faulty? backread signals?

    thanks for your help. i will do that. i've got another question i'd like advice on if possible but it's a different subject so i'll post a new topic! (v simple though probably for you)!! thanks again.
  7. L

    thermostate shower

    sounds like the thermostat element is faulty and allowing hotter water through so the colder water is making up for it (balancing it out). might need a new shower or just a new cartridge .... what's the make/model?
  8. L

    motorised vale faulty? backread signals?

    oh!! yes when i push the lever across and hooked it in position the pump and boiler started to work!! does this mean the motor is def. worn then and obviously not motoring across and switching on the pump and boiler automatically? new valve?
  9. L

    motorised vale faulty? backread signals?

    ok thanks for confirming that with me. so if white is live but ornage is not, then the valve motor is faulty. i might just replace the whole valve to be on the safe side and then it'll all be nice and new. but what about the backread signals situation? is this true or do i need not...
  10. L

    motorised vale faulty? backread signals?

    yes i know that is right - but for heating, orange should be live as well as white (as it will be calling for heat and thus making orange live to switch on power to pump and boiler).
  11. L

    motorised vale faulty? backread signals?

    Hi there I have a problem with my hot water and heating where none of them come on I have tested both my cylinder thermostat and my room/wall thermostat and both of their common terminals and call terminals are live when programmed on and turned up to max settings. so now i am going to...