  1. F

    Toilet soil pipe position

    I forget the exact details, but i was looking into this a few months ago, my local merchants had available for about £200 a close coupled with a connection that was much further forward then on many pans... Ask around..
  2. F

    polyplumb fittings

    If in any doubt, get rid of the fitting, replace the pipe and use new bits....piece of mind and not having water running throughout your house will make it worthwhile!
  3. F

    Combi Boiler Recomendations

    Fair enough! --saunters off to check facts and figures-- :oops:
  4. F

    polyplumb fittings

    Is the compression nut tight? Have you used inserts? Polyplumb has a ring of metal teeth in the fitting which grip the pipe, be very suprised to get any movement.
  5. F

    Struggling to go fully pumped

    What are your reasons for having to upgrade the whole system???
  6. F

    Combi Boiler Recomendations

    Worcester....much more sensibly sized boiler, those vaillant things are like pregnant ladies :lol:
  7. F

    dripping condenser flue

    I think he's saying it's normal for a viessmann to drip so don't worry :roll:
  8. F

    New gas meter coming - advice needed

    If the anaconda is on the supply side from the mains in the street, only transco can alter it, Internal pipes for domestic pipework can be altered by any RGI.
  9. F

    dripping condenser flue

    I hear what your saying but it doen't quite work that way....i have seen this fault and that was what the problem was. However appreciate your situation is probably quite diffferent (aren't they always :wink: )
  10. F

    Worcester 28CDI Combi

    http://www.worcester-bosch.co.uk/installer/literature/discontinued-boiler-literature/discontinued-gas-boiler-literature/28cdi-rsf-discontinued-june-2007-literature Bit long winded!! Here you can find your boiler installation intructions...at the back, each flashing light indicates a...
  11. F

    dripping condenser flue

    Flue only needs about a 3 degree fall, so not much, It's possible the condesate pipe (white about 3/4 inch diameter) is backing up...not so familiar with the boiler, but you can check the installation of this pipe and ensure it has no rise in it anywhere. Can check the condesate trap...
  12. F

    Heating Problem (and its cold tonight!!!)

    Unlabelled black switch is the manual lever, is assume it a two port?? put it into manual and leave open...heads just snap on and off so an easy replace... :D
  13. F

    Central Heating Leaking ? Pressure dropping

    Check that your pressure relief is not letting by, will be a 15mm copper pipe terminating on the external wall by your boiler. Could also be the secondary heat exchanger is pinholed and letting water from your CH to the hot circuit. Otherwise leak on pipes...laminate floor should be...
  14. F

    Heating Problem (and its cold tonight!!!)

    What make of valve is it?
  15. F

    Fast drip from Central Heating Overflow

    Type in 'pumping over' and 'blocked feed' as seperate searches..there's loads of advice there... :wink:
  16. F

    Solar Heating basics

    Get an air source system maybe?? Cost a little more then a new boiler install and electricity is comparable to gas now the prices have gone up so much.... Mind you...where does the electricty come from...great big coal fires :evil:
  17. F

    Combi Boiler / Hot Water / Shower Query

    How long do you intend to remain in your current property?? If more then 10 years, say, you'll have to replace it sometime and you may as well enjoy the best years of a new boiler yourself. Also save any money on repairs of an ageing boiler....
  18. F

    Bath mixer tap

    Yes, turn water for your property off at the stopcock and hot and cold will be off.
  19. F

    Boxing a Worcester Combination boiler in ????

    Probably a room sealed boiler though so no requirements for ventilation.