  1. K

    ATAG e32c BL81 Fault

    Evening all, Hope someone can help me out The above fault, no flue gas sensor fitted to this boiler( optional fit) harness seems ok and flow/return/dhw switch sensors seem ok..no visible issues, nice clean well maintained boiler...was working fine yesterday then this morning when dhw was...
  2. K

    Neighbour dispute so he's turned off my water supply! Help!

    As scatman says.....turn his water off in the street, stock up on bottled water first! then pour cement into the stopcock and see how he likes it....won`t help u much but it will **** him off!! :twisted:
  3. K

    57kw needed

    wat other gas appliances are in the house? if its only got a u6/g4 meter it doesn`t leave much left for cooker/fires....? how many rads has it got.....? much be huge house....
  4. K

    Glow worm Compact 100e Dhw prob

    yes, to change full diverter or to replace internals on it will require boiler to be drained
  5. K

    Glow worm Compact 100e Dhw prob

    diverter valve motor/ pcb or needs new DV cartridge is my guess providing burner pressures are all correct and plate heat ex is clean...
  6. K

    help!!

    coz they either don`t know wat the problem is or are just trying to blag you and make some money on a boiler swop job............... :cry:
  7. K

    is this normal for new boilers?

    the cheaper option would have been to get a good independant to do it probably :)
  8. K

    Glow worm compact 100e Pump question?

    picasso already answered your question...remove, do whatever your gonna do with it then re fit..
  9. K

    New Gas Boiler

    viessman
  10. K

    floor insulation

    Hi lads, i`ve got stripped wooden floors in most of my rooms downstairs in my house. looks great but bloody draughty! was planning on insulating between the floor joists to resolve this problem. i have a crawlable void underneath and my plan was to put spaceblanket insulation battened up in...
  11. K

    Luke warm water from ravenheat combi

    as above or maybe diverter valve, leave heating off til cold then run a hot tap and see if the htg flow pipe under boiler gets hot...if it does then its a diverter problem
  12. K

    New bath taps - pressure is lousy and hot tap is noisy

    are there isolators on each new tap pipework? if so are they fully open?
  13. K

    Combi pressure not dropping back down when cold

    the plate heat ex might be holed passing mains water into the system. if you pressure boiler to 1 bar, does pressure rise on its own if you don`t use the heating for a few hours? ( disconnect filling loop)
  14. K

    Copper or plastic & new radiatorsor re-use - opinions pl

    If problems with rodents in the past then copper would prob be the best way to go, 22mm runs with 15mm branches off to the rads. would reccommend older rads replaced dependant upon their individual condition. But of course the whole system should be prperly cleaned out before any new boiler is...
  15. K

    Warmfront big chill

    don`t go full ahead with full install, the system itself might not be as bad as you think, if the rads look ok ie no rust coming through, paint peeling off then they might just need a flush out. as for the boiler, virtually anything can be fixed/repaired! wherabouts blackpool area are you?
  16. K

    Warmfront big chill

    were all radiators new 7 years ago? what size pipework is connected to the rads?
  17. K

    worcester greenstar he plus 30

    its not been left on minimum rate has it? does the display look the same as normal?
  18. K

    Ravenheat RSF 84 Problems

    gat yourself htg and hw thermistor, numerous problems associated with these, bout 8 quid each, easy to change, do it whilst diverter is out, might as well
  19. K

    cant get cleaner in radiators

    if got 15mm pipework too upstairs rads, in the past i`ve drained down, then un done 1 trv/ls valve upstairs and tipped it into pipework........( sealed system)