    Ideal C95ff

    I have had a lot of problems with the Overheat Stats on these boilers mate.
  2. B

    Swiftflow 100e Failing Emissions

    New burner fitted and emissions are perfect from it now. Strange one the old burner appears fine. Oh well Job done so who cares
  3. B

    Swiftflow 100e Failing Emissions

    Anybody had probs with this b4?
  4. B

    Swiftflow 100e Failing Emissions

    Guys looking for a wee bit of advice, at a Swiftflow today took a Telegan and got 0.0124 after doing the following, cleaned heat exchanger, inspected burner for cracks, Burner pressures set up correctly, inner flue appears ok, fan running fine. Been working on these boilers for years and never...
  5. B

    Condensing Boilers at this time of year

    These boilers have proven to be a complete shambles during this big freeze. Despite being lagged they are still freezing up and not operating. Ive fitted a ridiculous amount of parts to numerous boilers past 2weeks with no cut-off on them. Potterton Promax springs to mind (Gas Valve, Fan , PCB...
  6. B

    Alpha CB24 - Hot & Cold -= Run out of ideas ? now =-

    That is an absolute embarrassment not finding that fault earlier. Even the most inexperienced of engineers would know to check the Min/Max Pressures. Shocking
  7. B

    24i junior

    Exactly its a strange sequence of operation totally different to majority of combi's. Bridge the switch out first and see if it fires then strip it out and clean it. If still faulty after cleaning replace the switch.
  8. B

    24i junior

    The Switch is probably blocked, strip it out and clean it
  9. B

    24i junior

    Had same fault today, stripped the Low Water Sensor and cleaned it out, put in back in and all ok
  10. B

    Central heating power flush, boiler now cutting out

    I must agree i read this forum a lot and Tony a lot of your comments are very condescending towards people. Im a fairly inexperienced engineer (around 5yrs on the tools) and you are the kind of person on a daily basis I hate coming across a Mr Know It All. No doubting your probably a fantastic...
  11. B

    Baxi Solo 2--"Fan on" light not illuminating--plea

    Best to get someone out to have a look, could possibly be the Air Pressure Switch
  12. B

    heatline s24 combi

    Couldnt really help mate, all i can say that ive had some hellish problems with these Heatline Boilers recently (one thing after another), one of the poorest manufacturers on the market. I would get yourself a Maintenance Contract asap to avoid further hassles down the line
  13. B

    potterton profile prima 60e

    Ive had some problems with the Wiring Harnesses on the profile range. On certain jobs ive had to change the PCB then the APS and stunned to find the fault hasnt been fixed. My mate works for Potterton and told me to change wiring harness and then it works
  14. B

    is this a sensible power flush quote?

    BG offer a first class Powerflush and ive never heard any complaints outwith the price, in my experience ive saw many a joke of a Flush being performed by "THE LOCAL PLUMBER" meaning that the customer ends up paying BG to do the flush correctly. Fair enough the quotes from BG may be a few...
  15. B

    leaking isolation valve

    Or makes it a thousand times worse! :shock:
  16. B

    vokera 20/80 rs turbo

    Vokera Flowmatic 20/80rs are well past there best, ridiculous amount of intermittent faults on those heaps of junk now. Get a new system fitted mate