    2 upstairs radiators on end of run not working (have bled)

    Sounds like the system needs balancing if you turn off the other rads in the house do the two cold ones get hot if so it needs balancing.
  2. B

    Initial interview with corgi & Portfolio

    I did a similar thing by doing a bepec domestic gas foundation course over a 12 months period, during which time I gained on the job experiance and built up a portfolio with a service engineer that works for CHN in the west midlands. I then took my acs after passing the bepec course and then...
  3. B

    High Pressure!

    If when the systems cold it always goes back to 1.3 bar and rises to around 2 bar when hot the it's normal for a system to do that yes.
  4. B

    Ferolli Modena 80 problems after changing thermsistors

    Might seam like a stupid question but did you close the isolating valves on the flow or return pipe under the boiler and if you did did you open them up fully.
  5. B

    Upstairs rads need constaint bleeding

    easy to test get a pint glass of water and put the end of the vent pipe into it if water gets sucked in then thats your problem have you changed the pump recently.