Search results

  1. D

    mira 88 shower

    is a mira 88 mixer shower suitable for use with a combi boiler?mixer was originally tank fed but obviously wont be if we change to a combi,just wondered if we needed to change mixer.thanks in advance
  2. D

    vola kitchen mixer

    anyone know how to remove spout on vola kitchen mixer?there is no grub screw, the o rings need replacing but cant get spout out.
  3. D

    size of cistern for shower

    i am fitting a new shower for ensuite,i have a 900/400 hot cylinder which will be supplied by cistern in loft just for this,no other outlets im hoping i'll have enough head so no need for pump,just wanted to know if i had to have 50 gallon tank or would 40 do,i may have to fit shower pump if...
  4. D

    vent pipe position

    i'm fitting hot water cylinder for new bathroom,the cwsc is not directly above it,is it ok to for vent pipe to go through ceiling then across loft about a metre before going up and over cistern.the cwsc is in middle of roof to allow it to be raised but vent pipe would come through at edge of...
  5. D

    size of cwsc

    hi all ,is a 25 gallon cwsc big enough to supply hot cylinder 36/18 and cold feed to shower,hot cylinder is just for shower too so no other outlets,would need small pump for shower as not enough head without one
  6. D

    water softener needs sterilising?

    anyone know how to sterilise a water softener thats been out of use for about a year,was not used due to flexis being kinked and leaking. have replaced and now want to get softener going again..
  7. D

    series 155 water conditioner

    hi all,can anybody tell me if it is ok to connect a series 155 water softener using copper instead of flexi pipes,the flexi pipes that are on it at the minute are too long and have been twisted and leak .If i can connect with copper pipe it will save me finding flexi's that are short enough...
  8. D

    grit in sink

    hi all,just ran mixer tap in friends house and when water had drained away it left what looked like a shovel full of sand in sink!tap has not been used much for 4 or 5 weeks prior 2 me using it,could this be a problem with water softener?will it clear with regular use or get worse?any ideas
  9. D

    pressure/flow required for 3 electric showers

    hi im currently turning 3 large cupboards into ensuites,no problem getting water to and from rooms but not sure water pressure required for the three electric showers i want to fit, im guessing i'll need at least 3 bar,could easily fit cistern in loft and run cold to single ended pump then run...