  1. C

    Recommend an alarm for my metal shed

    Sorry, sorry, sorry it is an elite 24 firmware 2.11 I think (I've just been back into wintex but couldn't find where the firmware version is, I can't remember where I saw 2.11) I have tried secureiam on the keypad, enter engineers code. 7 yes, 8 yes (should now be saying on...
  2. C

    Recommend an alarm for my metal shed

    Hi sparkymarka Check via keypad not wintex go to comm port set up , if you go to comm 1 and it says nothing fitted press reset that will clear the comm port of any errors , I did what you suggested it said nothing fitted , I pressed reset then came out of the menu's but it still says com...
  3. C

    Recommend an alarm for my metal shed

    Hi secureiam, my alarm is the premier 24 not the elite. I have a com port 1 fault at the moment and In wintex In the radio pad com port options I have onboard digi com as com2400 module com port 1 and 2 as nothing fitted com baud rate 2400 expansion port nothing fitted...
  4. C

    Recommend an alarm for my metal shed

    I have managed to get the alarm to text me but it still has com port 1 fault displayed? If I try to arm it says do I want to arm with faults. In wintex In the radio pad com port options I have onboard digi com as com2400 module com port 1 and 2 as nothing fitted com baud rate 2400...
  5. C

    Recommend an alarm for my metal shed

    cheers sparkymarka In area options, faults engineer reset is not chosen for A or B is this the option you are referring to? Thanks, Si
  6. C

    Recommend an alarm for my metal shed

    My latest update I HAVE A WORKING ALARM IN THE HOUSE AND SHED :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P :P I decided I wanted each keypad to local arm disarm via user options. I also switched zones 9 and 10 (mapped...
  7. C

    Recommend an alarm for my metal shed

    Hi just thought, maybe when I said "I just tried to arm the shed(area B) and nothing happened so I decided to check the detectors out. I went to eng and walk test. I chose area B but it showed *none*. Does this mean it can't see my 2 zone inputs into rkp 2 (area B)?" What I should have...
  8. C

    Recommend an alarm for my metal shed

    Again it's only me sorry :? Hi secureiam "Zones 9 and 10 have 2 wires in alarm and two wires tamper. zones will be guard area B and wiring type double pole/eol. " Previously on this post I have been advised to select normally closed . I actually don't have zones 9 + 10, I don't have...
  9. C

    Recommend an alarm for my metal shed

    Only me again In wintex if I have selected A for rkp 1 and B for rkp 2. So does that mean rkp1 will only arm area A and negate the need to press area when trying to arm ? Or do I have to select local arm disarm from user 1 options? again to negate the need for pressing area when arming...
  10. C

    Recommend an alarm for my metal shed

    Hello again, I enabled quick set on both keypads. I just tried to arm the shed(area B) and nothing happened so I decided to check the detectors out. I went to eng and walk test. I chose area B but it showed *none*. Does this mean it can't see my 2 zone inputs into rkp 2 (area B)? In...
  11. C

    Recommend an alarm for my metal shed

    Thanks again for your replies, I really appreciate it. I would basically like the shed (area B) to be totally separate from the house (area A) apart from if it goes into alarm I would like the digi modem to tell me, if thats possible? I would like to arm area B from either the house or the...
  12. C

    Recommend an alarm for my metal shed

    Sorry another question, do I have to tick system configuration option 33 - enable text to get the text I have assigned to each zone to show up? Thanks, Si
  13. C

    Recommend an alarm for my metal shed

    Went back in the loft and found 2 things. When I tried before with the link i'm guessing I didn't have it in tight enough because the fault cleared this time. Then I found a suspect broken wire in my tamper circuit, well suspect enough that as I tried to reinsert it broke off. All...
  14. C

    Recommend an alarm for my metal shed

    Cool, progress. It let me in. I went to the confirm devices menu and it shows rkp 1+2 or something like that and asked me if I wanted to confirm, I said yes. Then I had tamper faults but realized the panel was still open and my computer plugged in. I unplugged computer and closed panel and...
  15. C

    Recommend an alarm for my metal shed

    Hi thanks , I will untick eng + user in global, select normally closed very shortly and get back with my progress. No I haven't set up the 2400 yet I was going to ask that question later ;-) I have set keypad 2 and it's 2 detectors to area B and would like to be able to arm (area B the...
  16. C

    Recommend an alarm for my metal shed

    Hello again, On wintex the eng code comes up with 4 * If I use my user code or 5,6,7,8 I get the acknowledge beeps, if I use eng 1,2,3,4 I get "you need a user to enable access" so I'm guessing I haven't altered the number I've just altered something to allow it access. Just to clarify...
  17. C

    Recommend an alarm for my metal shed

    Is it system configuration option 37 EN 50131-1 grade 3 system? that was already un ticked. Thanks, Si
  18. C

    Recommend an alarm for my metal shed

    I did try the wiring type as normally closed and when I got my wife to walk infront of the detectors they worked on the diagnostics page, but as the system wouldn't let me do anything else I read more and thought the diagram on p28 (installation manual INS176 - 8 ) showing double pole looked...
  19. C

    Recommend an alarm for my metal shed

    Well I now have a premier 24 installed connected to the original detectors. I have replaced the keypad to a Premier LCD and fitted Premier keypad in the shed. My 8 core alarm cable is run in unistrut from the house to the shed. There is a door contact on the shed door and a texecom dual tech...
  20. C

    Recommend an alarm for my metal shed

    RF Lighting "All you need to send to the shed is a single 4 core alarm cable connected to the network terminals in the panel. This will run the keypad which also acts as a mini panel allowing you to connect two detectors and two outputs to it which will be enough for a pir, door contact and a...