Search results

  1. G

    Kitchen sink waste replacement

    Hi, We have a Blanco stainless kitchen sink which has an overflow feeding back to the outlet which is constantly getting black, both in the overflow pipe and the area below the plug. The sink also has a small half bowl, this doesn't have an overflow but the drain has what looks the same as...
  2. G

    Non return valve suitable for h/w cylindr outlet?

    Hi, Back home from a 3 day break to see the cylinder header tank outlet pipe dripping at approx 2 drops per second over the front door canopy. This has happened before and previuosly, I replaced the float valve and attended to the replacement once more. However, thinking that they were...
  3. G

    Garage Consumer bust following buliding work.

    Hi hopefully someone may be able to oofer some advice regarding a faulty Contactum Metal supply that has been installed in our shed. A little history....... We have a 10 way split load unit in the kithchen which has an RCD for one side of the box. The shed is wired from the RCD side with SWA...
  4. G

    What cable for bulkhead in garden?

    We have a garden shed fed from the house with SWA cable to an RCD and MCB box. This then feeds an internal light and 2 sockets. There is a second run of SWA which connects via a metal box for Earth to a small run of flex on and a plug which powers an external plastic box. The external box is...
  5. G

    TRV functionality when weather changes.

    Hi, We have a Remeha system boiler in the kitchen extension, with a Honeywell CM927 managing the temp with the the sensor in the extension as that's the coldest room. That works well, no problems. However, some of the rads were changed and also had TRV's fitted (Pegler Bulldogs). It seems...
  6. G

    Remeha Avanta 24S CH fails to start intermittently.

    We have had this system boiler since February. I have have previously replaced a Sunvic wired thermostat with a wireless Salus, well two infact, as I belived they had failed. Both indicated power at the receiver, the relay clicked but the boiler did not fire. The timer has been set to "on"...
  7. G

    Replace Sunvic TLX with Honeywell CM927 help please.

    Following on from a previous post, I have purchased the CM927 and would like some advice please. For info, Remeha Avanta system boiler, timer below, Sunvic Thermostat in the hall. Previously had a Salus RT500RF but two receivers failed so now going to try the Honeywell. The Sunvic has been...
  8. G

    Honeywell CM927 Thermostat replacement for Salus RT500RF.

    Hi, I am seeking some help prior to purchasing the Honeywell as a replacement to the Salus. For information, we have a (?system) boiler in the kitchen extension and the thermostat is in the hallway. Originally it was (and has just gone back on) a simple Sunvic, with the timer in the...
  9. G

    Salus RT500RF Occasional failure to start boiler.

    I have been using the Salus to control the temp in the house due to a cold extension. The timer is correctly set, and most of the time, everything is good. The problem is, occasionaly, when the sender demands heat, the reciever clicks and glows green but the boiler (Remeha avanta) does not...
  10. G

    Angled concrete fence posts.

    Looking into moving our existing fencing (subject to planning), to extend into our side garden which is beyond the current fence and am faced with how to angle the fencing. We have a plot of land to the side, which we have previously extended into, but folowing some building work, would like...
  11. G

    Maximum gap that can be sealed with silicone?

    Hi, I have recently had some plaster work done and decided to include attending to the finish of a recently installed door into the job. The installers of the door trimmed both the inside and exterior of the door with a plastic trim, due to the new door being of a slimmer profile than the...
  12. G

    Replacement boiler: keep it vented?

    Shortly, we are to replace our 22 year old Baxi system boiler (two tanks in the loft) and believe it to be a vented system. The existing boiler is within a cupboard in the kitchen and this is where the new one will go. I do not want any more mess than necessary and am happy to keep the...
  13. G

    Help needed to change a Sunvic stat to a wireless Salus stat

    Hi, We have an old Baxi system boiler with a timer below it, in the kitchen and a hot water cylinder upstairs, the Sunvic TLX 2259 stat is in the hall way. I have studied these forums and the instructions of both the Sunvic and a replacemnt Salus RT300RF with the intention of taking the...
Back