Search results

  1. M

    Sime Super 102 Blowing PCB 1.6A Fuse as soon as HW or CH called

    Hi guys A few months ago the boiler stopped working and it turned out to be a blown F1.6A fuse on the PCB. Replaced that and it carried on working fine for a few months. Last night however again it blew the fuse but now when i replace the fuse everything is ok until i call for hot water or the...
  2. M

    HELP! Sime Super 102 no hot water or CH

    Hello! Its been 4 days already and i still havent managed to trace the fault. It started a few days ago when the fan stopped working, then it worked for a day and now nothing works. I replaced the fan (it needed replacing as it was making too muchj noise) and i replaced the limit...
Back
Top